7 | Commissioning
20 | 44 Instruction Manual TYR WT 0100-0730 CP CV_EN_en
7 Commissioning
CAUTION
During operation the surface of the machine may reach temperatures of more than 70°C.
Risk of burns!
Avoid contact with the machine during and directly after operation.
CAUTION
Noise of running machine.
Risk of damage to hearing!
If people are present in the vicinity of a machine that is not insulated from noise for extended peri-
ods of time:
Make sure to wear hearing protection.
Make sure that the Installation Conditions [11] are met.
Start the machine.
Make sure that the maximum permissible number of starts does not exceed the following recom-
mendations:
From 3 kW to 11 kW 12 starts per hour
From 15 kW to 90 kW 6 starts per hour
Make sure that the operating conditions comply with the Technical Data [36].
After a few minutes of operation, perform an Oil Level Inspection [25].
As soon as the machine is operated under normal operating conditions:
Measure the motor current and record it as reference for future maintenance and trouble-
shooting work.
NOTICE
The machine can be shipped without oil.
Operation without oil will ruin the machine in short time!
Prior to commissioning, the machine must be filled with oil, see Filling Oil [14].
NOTICE
Lubricating a dry running machine (compression chamber).
Risk of damage to the machine!
Do not lubricate the compression chamber of the machine with oil or grease.