7 | Commissioning
20 | 44 Instruction Manual TYR WT 0100-0730 CP CV_EN_en
7 Commissioning
CAUTION
During operation the surface of the machine may reach temperatures of more than 70°C.
Risk of burns!
● Avoid contact with the machine during and directly after operation.
CAUTION
Noise of running machine.
Risk of damage to hearing!
If people are present in the vicinity of a machine that is not insulated from noise for extended peri-
ods of time:
● Make sure to wear hearing protection.
● Make sure that the Installation Conditions [➔11] are met.
● Start the machine.
● Make sure that the maximum permissible number of starts does not exceed the following recom-
mendations:
From 3 kW to 11 kW 12 starts per hour
From 15 kW to 90 kW 6 starts per hour
● Make sure that the operating conditions comply with the Technical Data [➔36].
● After a few minutes of operation, perform an Oil Level Inspection [➔25].
As soon as the machine is operated under normal operating conditions:
● Measure the motor current and record it as reference for future maintenance and trouble-
shooting work.
NOTICE
The machine can be shipped without oil.
Operation without oil will ruin the machine in short time!
● Prior to commissioning, the machine must be filled with oil, see Filling Oil [➔14].
NOTICE
Lubricating a dry running machine (compression chamber).
Risk of damage to the machine!
● Do not lubricate the compression chamber of the machine with oil or grease.