Maintenance | 8
Instruction Manual TYR WT 0100-0730 CP CV_EN_en 25 | 44
8.4 Maintenance Oil
Interval Maintenance work
After 10-20 operating hours ● Check the oil level,
see Oil Level Inspection [➔25].
Weekly ● Check the oil level,
see Oil Level Inspection [➔25].
After 500 operating hours ● Change for newly operated blower.
Every 8000 hours ● Change the oil (min. once a year).
8.5 Oil Level Inspection
● Shut down the machine.
● When the machine is stopped, wait 1 minute before checking the oil level.
● Fill up if necessary, see Oil Filling [➔14].