5 | Installation
14 | 44 Instruction Manual TYR WT 0100-0730 CP CV_EN_en
5.3.2 Discharge Connection
NOTICE
Discharge gas flow obstructed.
Risk of damage to the machine!
● Make sure that the discharged gas will flow without obstruction.
Connection size(s):
– Ø 114 mm for WT 0100 CV/CP and WT 0150 CV/CP
– Ø 159 mm for WT 0280 CV/CP and WT 0390 CV/CP
– Ø 219 mm for WT 0600 CV/CP and WT 0730 CV/CP
Depending on the specific configuration ordered, other connection dimensions may apply.
● Make sure that the connection lines cause no stress on the connections of the machine. There-
fore, we recommend installing flexible joints on the suction and discharge connections.
5.4 Filling Oil
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
● Only use an oil type which has previously been approved and recommended by Busch.
For oil type and oil capacity see Technical Data [➔36] and Oil [➔38].
When the oil filling is achieved:
● Write down the oil change date on the sticker.
Last oil change
__ / __ / ____
Oil type see nameplate
Change interval see
instruction manual
If there is no sticker (part no. 0565 568 959) on the machine:
● Order it from your Busch representative.