EasyManua.ls Logo

BWT BEWADES blue 0.5 - User Manual

BWT BEWADES blue 0.5
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1-510875 / 12538 / 2019-08 / © BWT Wassertechnik GmbH
Changes reserved!
Änderungen vorbehalten
Sous réserve de modications !
BEWADES blue
UV disinfection systems
0.5 / 1.0 / 2.0 / 2.5 / 3.5
UV-Desinfektionsanlagen
0.5 / 1.0 / 2.0 / 2.5 / 3.5
Systèmes de désinfection UV
0.5 / 1.0 / 2.0 / 2.5 / 3.5
Installation and operating manual EN
Einbau- und Bedienungsanleitung DE
Instructions de montage et d‘utilisation FR

Table of Contents

Questions and Answers

Summary

Safety Instructions

General safety instructions

Provides essential safety guidelines for product operation, handling, and maintenance.

Scope of the documentation

Defines the applicability of the manual to specific product versions and target audiences.

Personnel qualifications

Specifies the required expertise for installation and operation, distinguishing between qualified specialists and instructed persons.

Transport and installation

Outlines precautions for safe handling during transport and initial setup.

Symbols used

Explains the meaning of various symbols and pictograms used throughout the manual for hazard communication.

How safety instructions are displayed

Details the format and structure of safety information, including signal words and hazard descriptions.

Product-specific safety instructions

Highlights critical safety warnings and procedures directly related to the device's operation and potential hazards.

List of supplied parts

Use

Proper use

Defines the intended application of the UV disinfection unit for drinking water.

Foreseeable misuse

Lists conditions and actions that constitute improper use of the unit, voiding warranty.

Disclaimer

States manufacturer's limitations of liability regarding unauthorized modifications or non-compliance.

Other applicable documentation

Advises users to observe all provided supplier documents for complete system understanding.

Function

Design of UV units

Explains the core design principles, components, and UVC ray generation for disinfection.

Possible flow rates of the system

Discusses system rating based on water quality and flow rates, and the impact of exceeding them.

Installation conditions

Installation site and environment

Specifies requirements for the installation location, including temperature, frost protection, and electromagnetic interference.

Feed water

Details the necessary water quality parameters and hydraulic conditions for optimal system performance.

Installation

Provides guidance on pipe material selection, filtration, and pre-treatment considerations.

Installation diagram

Assembly of the UV unit

Cleaning the quartz glass sleeve

Provides step-by-step instructions for safely cleaning the quartz glass sleeve to maintain UV transmittance.

Cleaning the UV sensor

Details the procedure for cleaning the UV sensor to ensure accurate intensity measurements.

Operation

BWT control display

Describes the functions and features of the full-colour LCD control display for system monitoring.

Automatic start sequence of the unit

Explains the power-up diagnostic sequence and module initialization process.

Operational screens (of non-monitored version)

Details the displays and navigation for units without UV-sensor monitoring.

Operational screens (of monitored version)

Describes the UV intensity monitoring screens and warning indicators.

Remaining lifespan countdown of UV lamps (in days)

Explains the system's countdown for lamp replacement and associated warnings.

UV lamp replacement

Provides instructions for safely replacing the UV lamp and its associated key.

QR codes

Guides users on accessing additional product and maintenance information via QR codes.

System Troubleshooting

Options

Expansion modules

Describes additional modules like UV sensors and their connection via the Infinite Expandability Port (IEP).

Remote alarm connection module

Explains how to connect remote devices for alarms, status indication, or system control.

4-20 mA module (option)

Details the module for outputting UV intensity signals to external data loggers or computers.

Operators responsibilities

Intended operation

Outlines the operator's duties including commissioning, operation, and decommissioning.

Inspections (by the operator)

Lists routine checks the operator must perform, covering water pressure, quality, and system status.

Inspections (according to EN 806-5 by the operator)

Specifies periodic inspection activities and intervals required by EN 806-5 for the operator.

Maintenance according to EN 806-5

Details part replacement cycles and cleaning schedules for wearing parts as per EN 806-5.

Technical specifications

Water Quality Parameters

Defines critical water quality parameters essential for effective UV disinfection and pretreatment recommendations.

Warranty terms

Decommissioning and disposal

Decommissioning

Provides instructions for safely shutting down and dismantling the unit by qualified personnel.

Disposal

Outlines proper methods for disposing of the unit, packaging, batteries, and lamps, respecting regulations.

Standards and legal provisions

Summary

Safety Instructions

General safety instructions

Provides essential safety guidelines for product operation, handling, and maintenance.

Scope of the documentation

Defines the applicability of the manual to specific product versions and target audiences.

Personnel qualifications

Specifies the required expertise for installation and operation, distinguishing between qualified specialists and instructed persons.

Transport and installation

Outlines precautions for safe handling during transport and initial setup.

Symbols used

Explains the meaning of various symbols and pictograms used throughout the manual for hazard communication.

How safety instructions are displayed

Details the format and structure of safety information, including signal words and hazard descriptions.

Product-specific safety instructions

Highlights critical safety warnings and procedures directly related to the device's operation and potential hazards.

List of supplied parts

Use

Proper use

Defines the intended application of the UV disinfection unit for drinking water.

Foreseeable misuse

Lists conditions and actions that constitute improper use of the unit, voiding warranty.

Disclaimer

States manufacturer's limitations of liability regarding unauthorized modifications or non-compliance.

Other applicable documentation

Advises users to observe all provided supplier documents for complete system understanding.

Function

Design of UV units

Explains the core design principles, components, and UVC ray generation for disinfection.

Possible flow rates of the system

Discusses system rating based on water quality and flow rates, and the impact of exceeding them.

Installation conditions

Installation site and environment

Specifies requirements for the installation location, including temperature, frost protection, and electromagnetic interference.

Feed water

Details the necessary water quality parameters and hydraulic conditions for optimal system performance.

Installation

Provides guidance on pipe material selection, filtration, and pre-treatment considerations.

Installation diagram

Assembly of the UV unit

Cleaning the quartz glass sleeve

Provides step-by-step instructions for safely cleaning the quartz glass sleeve to maintain UV transmittance.

Cleaning the UV sensor

Details the procedure for cleaning the UV sensor to ensure accurate intensity measurements.

Operation

BWT control display

Describes the functions and features of the full-colour LCD control display for system monitoring.

Automatic start sequence of the unit

Explains the power-up diagnostic sequence and module initialization process.

Operational screens (of non-monitored version)

Details the displays and navigation for units without UV-sensor monitoring.

Operational screens (of monitored version)

Describes the UV intensity monitoring screens and warning indicators.

Remaining lifespan countdown of UV lamps (in days)

Explains the system's countdown for lamp replacement and associated warnings.

UV lamp replacement

Provides instructions for safely replacing the UV lamp and its associated key.

QR codes

Guides users on accessing additional product and maintenance information via QR codes.

System Troubleshooting

Options

Expansion modules

Describes additional modules like UV sensors and their connection via the Infinite Expandability Port (IEP).

Remote alarm connection module

Explains how to connect remote devices for alarms, status indication, or system control.

4-20 mA module (option)

Details the module for outputting UV intensity signals to external data loggers or computers.

Operators responsibilities

Intended operation

Outlines the operator's duties including commissioning, operation, and decommissioning.

Inspections (by the operator)

Lists routine checks the operator must perform, covering water pressure, quality, and system status.

Inspections (according to EN 806-5 by the operator)

Specifies periodic inspection activities and intervals required by EN 806-5 for the operator.

Maintenance according to EN 806-5

Details part replacement cycles and cleaning schedules for wearing parts as per EN 806-5.

Technical specifications

Water Quality Parameters

Defines critical water quality parameters essential for effective UV disinfection and pretreatment recommendations.

Warranty terms

Decommissioning and disposal

Decommissioning

Provides instructions for safely shutting down and dismantling the unit by qualified personnel.

Disposal

Outlines proper methods for disposing of the unit, packaging, batteries, and lamps, respecting regulations.

Standards and legal provisions

BWT BEWADES blue 0.5 Specifications

General IconGeneral
Product TypeWater Filtration System
BrandBWT
ModelBEWADES blue 0.5
Filtration TechnologyIon Exchange
Capacity0.5 m³/h
Operating Pressure2 - 8 bar
Operating Temperature5 - 35 °C
RegenerationAutomatic
Water Hardness ReductionYes
Connection Size1 inch
WeightApprox. 25 kg

Related product manuals