EasyManua.ls Logo

C-Max VIGO - Repeat Cast on New Swift Message; Repeat Cast after X Minute(S); Repeat Cast Every X Meters

Default Icon
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Automatic repeat options available
Each of these options is exclusive, and can be enabled and disabled at any time before or during a
cast. A description of each repeat mode is given below.
Repeat Cast on New SWiFT Message
This option will repeat the cast immediately upon receiving a new message from Connect.
Repeat Cast after ‘x’ minute(s)
This option will repeat the cast after a user definable number of minutes have elapsed. The timer
starts when the software has completed the current cast and has received a new message from
Connect, not when the previous cast was started.
Allowable values for this mode are 1 minute (minimum) to 60 minutes (maximum).
Repeat Cast every ‘x’ meters
This option will repeat the cast after the vessel has travelled a certain distance from the point at which
the previous cast was started. This distance is calculated using the Haversine formula, and is the
distance in a straight line, not the distance travelled along a track. This option requires that the
previous cast has completed and the software has received a new message from Connect before it
will initiate another cast.
Allowable values for this mode are 250m (minimum) to 5000m (maximum).
32