Using Luna
62 ©2019 CAE 905K560252 v1.0
CAELuna
Genitourinary System
The manikin may be configured with either male or female genitalia, and both configurations are
capable of urinary catheter insertion.
Replace Genitalia
To change the genitalia:
1. Apply cottonseed oil (found in accessory kit) to the block on the backside of the genitalia
prior to inserting.
2. Peel back skin around manikin’s genitalia and pull the current genitalia piece out.
3. Replace with the desired genitalia by aligning the block and peg on the genitalia with the
corresponding holes on the manikin.
Genitalia Replacement
4. Cover the outline of genitalia with manikin’s skin.
Urinary Catheter Insertion
To insert the urinary catheter, gently thread a lubricated catheter into opening of the genitalia: 10 cm
for female, 12 cm for male.
When the valve is engaged, a fluid flashback occurs. With the fluid receptacle already filled, a realistic
urinary catheterization with fluid release can be performed.