Pag. 16 - FA01497M4A - 03/2021 - © CAME S.p.A. -
Changing operating mode on OUT2
The procedure for changing a function on OUT2 can be performed from the S0002P card or the
keypad selector.
From the S0002P card
1
Press the delete all code key ❸(CLEAR).
The warning LED remains on.
Deleting users
Users can only be deleted from the keypad selector.
Single user
1
Use the keypad to enter the installer password
and press the following keys in sequence: (#),
(7), (#).
2
Enter the position number of the user you want
to delete (see table 󱵦) followed by the (#) key.
3
Confirm the position number of the user
followed by the (#) key.
A long beep will sound from the
selector to confirm.
If the number is not found in
the memory or is incorrect, the
selector will emit 10 short beeps.
To interrupt the procedure, press the (*) key and the selector will emit 3 short beeps;
alternatively, wait for 20 seconds.
All users
1
Use the keypad to enter the installer password
and press the following keys in sequence: (#),
(7), (#)
2
Press the (0) key three times followed by the
(#) key.
3
Press the (0) key again three times followed by
the (#) key
A long beep will sound from the
selector to confirm.
To interrupt the procedure, press the (*) key and the selector will emit 3 short beeps;
alternatively, wait for 20 seconds.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAME 8K06SL-007 and is the answer not in the manual?

CAME 8K06SL-007 Specifications

General IconGeneral
BrandCAME
Model8K06SL-007
CategoryGate Opener
LanguageEnglish

Related product manuals