L
N
+ E
-
EbA EbA EbI EbI
10
S2
S12EM432111
Pag.
- Manual code:
119 G3074 ver.
0.1 02/2009 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Once the turnstile is secured to the ground, car-
ry out the following cable connections.
Run through the conduits as shown in the figure
and carry out the shown connections.
The cables inserted into the electrical panel
box must be secured using the apposite
cable gland.
7 Electric cabling
7.1 Cable types and sections
N.B. If the cable length differs to that shown in the table, determine cable section based on the actual power draw by the connected
devices and according to what is prescribed by law CEI EN 60304-1.
For sequential connections on the same line, length-measurements by the table must be converted on the basis of draw and actual
distances.
To connect any products not mentioned in this manual, see documentation provided with said products.
Connections Cable types Cable length 1 < 10 m
Cable length
10 < 20 m
Cable length
20 < 30 m
Power to electrical panel 230V
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1,5 mm
2
3G x 2,5 mm
2
3G x 4 mm
2
Power to accessories 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1 mm
2
Command and safety devices 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
FUSE TABLE
To protect: Fuse rating:
Control board (line) 1,6A-F
Accessories 1,6A-F
The control panel is powered by 230V A.C. on terminals L-N, with
max frequency of 50/60Hz.
The 24V current emitted by the board is of the SELV type.
The command and control devices and accessories are 24V D.C..
Warning! The accessories must not comprehensively exceed
35W.
All connections are quick-fuse protected, see table.
The functions and user interface are set and displayed on the
software-managed display.
The defi nable command and control functionalities are:
- clock-wise activation;
- counter clock-wise activation;
- override release command;
- emergency command.
WARNING: before doing any work inside the equipment, cut the
power mains.
8.1 General description
8 Control panel
Intelligent Security & Fire Ltd.