ON
2
1345678910
Pag.
20
20 - Manual code:
119BU50
119 B U 50 ver.
2
04/2014 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
With two coupled gearmotors, you can command only the opening (by button and/or radio control): the gate will close only in automatic
closing mode.
Coordinate the direction of travel of the two gearmotors 󱤨 and 󱤩, by modifying the motor's rotation 󱤩 (invert the cables on
terminals FA-FC and M-N).
Make the electrical connections only on
the motor's control board 󱤨.
12 Connecting two coupled gearmotors having a single control
Whereas, the adjustments and features, must be made on both boards.
Connect the two boards together, as illustrated.
Set DIP 2 and 1 to ON on both boards.
For opening with a radio control, connect an external receiver (RExxx/RBExxx with relay in MONOSTABLE mode) on terminals 2-7 of