EasyManua.ls Logo

CAME BX-246 - Electrical Connections Overview

CAME BX-246
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ON
2
1345678910
13
16
4
17
5
6
7
12
10
18
8
9
3
14
2
1
14
15
19
-.
%$&#&!&
-.
%$&#&!&
COM
NC
NC
COM
COM
NC
NC
COM
11
Pag.
12
12 - Manual code:
119BU50
119 B U 50 ver.
2
04/2014 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Orange
Orange
White
Red
Black
Red
White
Red
6.3 Electrical connections
24 V (DC) motor
with encoder
Closing microswitch
Gearmotor, endstop and encoder
Modifications to the electrical connections for right-hand installations
Invert the gearmotor (U-V) and (FA-FC) endstop phases.
Opening microswitch
Description of the standard electrical connections for left-hand installations

Related product manuals