Functions map
F 1 Total stop function (1-2)
F 2 Function associated to input CX
F 3 Function associated to input CY
F 5 Safety test function
F 6 Maintained action function
F 9 Obstruction detection with motor idle function
F 10 Warning light function
F 11 Encoder exclusion
F 14 Sensor type selection function
F 15 Intermittent luminous cord function
F 18 Additional light function
F 19 Automatic closing time
F 21 Preflashing time
F 22 Working time
F 25 Courtesy light time
F 28 Adjusting opening speed
F 29 Adjusting closing speed
F 30 Adjusting opening slow-down speed
F 31 Adjusting closing slow-down speed
F 33 Adjusting calibration speed
F 34 Sensitivity during movement
F 35 Sensitivity during slow-down
F 37 Adjusting the opening slow-down starting point
F 38 Adjusting the closing slow-down starting point
F 49 Enabling serial connections
F 50 Saving data in memory roll
F 51 Reading memory roll data
F 52 Transferring parameters from Master to Slave
F 60 Sleep Mode function
F 61 Pre-flashing function
U 1 Type of command to associate to a user via radio control
U 2 Deleting single users
U 3 Deleting all users
A 1 Boom-type setting
A 2 Motor test
A 3 Calibrating boom travel
A 4 Resetting parameters
A 5 counting the number of maneuvers
H 1 Software version
Functions menu
F1 Total stop [1-2] 0 = Deactivated (default) / 1 = Activated
NC input - boom stop while excluding any automatic stop; to resume movement, use a control device. Connect the safety device to 1-2.
F2 Input [2-CX] 0 = Deactivated (default) / 1 = C1 / 4 = C4 / 5 = C5 / 9 = C9
NC Input - For associating: C1 = reopening during closing for photocells, C4 = obstruction wait, C5 = immediate closing, C9 = immediate
closing with obstruction wait when closing.
F3 Input [2-CY] 0 = Deactivated (default) / 1 = C1 / 4 = C4 / 5 = C5 / 9 = C9
NC Input - For associating: C1 = reopening during closing for photocells, C4 = obstruction wait, C5 = immediate closing, C9 = immediate
closing with obstruction wait when closing.
IMPORTANT! Start programming by first performing the following: A1 BOOM-TYPE SETTING, A2 MOTOR TEST, F1 TOTAL STOP
and A3 CALIBRATING BOOM TRAVEL.

Other manuals for CAME G4040E