F5 Safety test 0 = Deactivated (default) / 1 = CX / 2 = CY / 3 = CX+CY
After every opening or closing command, the board will check whether the photocells are working properly.
F6 Maintained action 0 = Deactivated (default) / 1 = Activated
The barrier opens and closes by keeping one button pressed. Opening button on 2-3 and closing button on 2-4. When this function is
activated, all other control devices, even radio ones, are excluded.
F9 Obstruction detection with motor idle 0 = Deactivated (default) / 1 = Activated
With the barrier closed, open or after a total stop, the operator stays still if the safety devices (photocells and sensitive edges) detect an
obstruction.
F10 Warning light 0 = lit with boom raised and moving (default) /
1 = fl ashes intermittently each half second when opening
when closing it fl ashes intermittently every second
permanently lit with the boom raised
o with the boom lowered
It warns of the barrier status. The light bulb is connected to 10-5.
F11 Excluding the encoder 0 = encoder activated (default) / 1 = encoder deactivated
It excludes management of slow downs, obstruction detection and sensitivity.
F14 Sensor type selection 0 = transponder sensor or magnetic card reader command
1 = control with keypad selector (default)
Setting the type of sensor for controlling the barrier.
F 15 Luminous cord intermittance 0 = Moving boom (default) /1 = Moving and closed boom
It warns of the status of the barrier with intermittent lights.
F18 Additional light 0 = Flashing light( default ) / 1 = Cycle / 2 = Courtesy
Output on [10-E1].
The fl ashing light works when opening and closing.
The cycle lamp stays on from the moment in which the barrier starts opening until it closes completely (including the automatic closing time).
In case the automatic closing is not inserted, it stays on only during the movement.
The courtesy light stays on for a fi xed 180 seconds or it can be adjusted, see function F 25.
F19 Automatic closing time 0 = Deactivated (default) / 1 = 1 s / 2 = 2 s / … / 180 = 180 s
The fi rst automatic-closing wait starts when the opening endstop point is reached and can be set to between 1 and 180 seconds. The
automatic closing does not activate if any of the safety devices trigger when an obstruction is detected, after a total stop or during a power
outage.
F21 Prefl ashing time 0 = Deactivated (default) / 1 = 1 s / … / 5 = 5 s
After an opening or closing command, the fl ashing light connected to 10-E1, fl ashes from 1 to 10 seconds before the maneuver starts.
F22 Working time 5 = 5 s / ...../ 120 = 120 s (default)
Gearmotor working time during opening and closing.
The working time can be adjusted between 5 and 120 seconds.
F25 Courtesy light time 5 = 5 s / ...../ 120 = 120 s (default).
Supplementary light, that stays lit during the barrier's opening and closing movement.
The time may be adjusted between 5 and 120 seconds
F28 Opening maneuver speed 70 = Minimum speed / … / 100 = Maximum speed.
Setting the boom's opening speed, calculated as a percentage.
⚠
Warning: the speed parameter fi elds vary depending on the type of boom:
- for jointed booms, of 2 m and 4 m, set the speed percentage to between 70 and 100;
- for booms of 6 m and 8 m, set the speed percentage to between 80 and 100.
F 29 Closing maneuver speed 70 = Minimum speed / … / 100 = Maximum speed.
Setting the boom's closing speed, calculated as a percentage.
⚠
Warning: the speed parameter fi elds vary depending on the type of boom:
- for jointed booms, of 2 m and 4 m, set the speed percentage to between 70 and 100;
- for booms of 6 m and 8 m, set the speed percentage to between 80 and 100.