Page 20 - Manual FA01383-EN - 04/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Command and control devices
1
STOP button (NC contact)
This stops the boom and excludes automatic closing. Use a control device to resume movement.
If the contact is not used, it must be deactivated during programming.
2
Control device (NO contact)
OPEN ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during OPENING.
3
Control device (NO contact)
PARTIAL OPENING function
The contact must only be used for operators working in paired mode.
4
Control device (NO contact)
CLOSE ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during CLOSING.
5
Control device (NO contact)
OPEN-CLOSE function
6
Card reader
7
Transponder selector switch
8
Keypad selector
9
Antenna with RG58 cable
1233P4572CXCYCZ
AB
S1 GND