6
7
AF
ON
2
1 3 4 5 6 7 8 9
10
DIP SWITCH (1-10)
ITALIANO - ENGLISH - ESPAÑOL
ITALIANO - ENGLISH - ESPAÑOL
SELEZIONI FUNZIONI /
FUNCTION SELECTIONS
/
SELECCIONES DE LAS FUNCIONES.
1 ON Funzione chiusura automatica
attivata; (1 OFF-disattivata)(da
abilitare solo sulla barriera
MASTER);
2 ON Funzione "apre" con trasmettitore
radio (scheda AF inserita)
attivato(da abilitare solo sulla
barriera MASTER);
2 OFF Funzione "apre-chiude-inversione"
con pulsante (2-7) e trasmettitore
radio (scheda AF inserita)
attivato(da abilitare solo sulla
barriera MASTER);
3 ON Funzione ad "azione mantenuta"
(esclude la funzione del
trasmettitore radio) attivato; (3
OFF disattivato)(da abilitare solo
sulla barriera MASTER);
4 ON Prelampeggio in apertura e in
chiusura attivato, con dispositivo
collegato sui morsetti 10- E7 (4
OFF disattivato)(da abilitare solo
sulla barriera MASTER);
5 ON Rilevazione ostacolo. A motore
fermo (barriera chiusa, aperta o
dopo un comando di stop totale),
impedisce qualsiasi movimento
se i dispositivi di sicurezza (es.
fotocellule) rilevano un ostacolo
(5 OFF disabilitato)(da abilitare
solo sulla barriera MASTER);
6 OFF Funzione di stop totale (collegare
pulsante su 1-2) attivato;(se non
utilizzato posizionare il dip in ON);
7 OFF Funzione di riapertura in fase di
chiusura (collegare i dispositivi
di sicurezza sui morsetti 2-
C1) attivata; (se non utilizzato
posizionare il dip in ON);
8 ON Funzione del test di sicurezza
per la veri ca dell’ef cienza delle
fotocellule (pag. 6) attivato; (8 OFF
disattivata).
9 OFF Encoder attivato per la gestione
dei rallentamenti in apertura e
chiusura degli ostacoli (9 ON
disattivato);
10 Non utilizzato
1 ON Automatic closing function
enabled; (1 OFF-disabled)(to be
enabled only on the MASTER
barrier);
2 ON “Open” function with radio
transmitter (AF board inserted)
enabled(to be enabled only on
the MASTER barrier);
2 OFF Function “open-close-reverse”
with pushbutton (2-7) and radio
transmitter (AF board inserted)
enabled(to be enabled only on
the MASTER barrier);
3 ON “Maintained action” function
(excludes the radio transmitter)
enabled; (3 OFF disabled)(to be
enabled only on the MASTER
barrier);
4 ON Pre- ashing while opening and
closing enabled, with device
connected to terminals 10-E7 (4
OFF disabled)(to be enabled only
on the MASTER barrier);
5 ON Obstacle detection. With motor
not running (barrier closed, open
or after a total-stop command),
all movement is prevented if the
safety devices (e.g. photoelectric
cells) detect an obstacle (5 OFF
disabled)(to be enabled only on
the MASTER barrier);
6 OFF Total-stop function (connect
pushbutton to 1-2) enabled; (if not
used, set dip-switch to ON);
7 OFF Re-opening during closure func-
tion (connect the safety devices
to terminals 2-C1) enabled; (if not
used, set dip-switch to ON);
8 ON Safety test function to check
photoelectric cell ef ciency (page
6) enabled; (8 OFF disabled).
9 OFF Encoder enabled for managing
obstacle slow-downs during ope-
ning and closing (9 ON disabled);
10 Not used
1 ON Función cierre automático
activa; (1 OFF-desactivada)(se
habilita sólo en la barrera
MASTER);
2 ON Función “abrir” con transmisor
radio (tarjeta AF conectada)
activa (se habilita sólo en la
barrera MASTER);
2 ON Función “abrir- cerrar- inver-
sión” con botón (2-7) y trans-
misor radio (tarjeta AF conec-
tada) activa (se habilita sólo en
la barrera MASTER);
3 ON Función “accionamiento con-
tinuo” (excluye la función del
transmisor radio) activa (3 OFF
desactivada) (habilitar sólo en
la barrera MASTER);
4 ON Predestello en apertura y en
cierre activo , con dispositivo
conectado en los bornes10- E7
(4 OFF desactivada) (se habili-
ta sólo en la barrera MASTER);
5 ON- Detección de obstáculos. Con
el motor detenido (barrera
cerrada, abierta o después de
un mando de parada total), im-
pide cualquier movimiento si
los dispositivos de seguridad
(por. ej. fotocélulas) detectan
un obstáculo (5 OFF deshabi-
litada) (se habilita sólo en la
barrera MASTER);
6 OFF Función de parada total (co-
necte el botón en 1-2) activa;
(si no se utiliza, coloque el dip
en ON);
7 OFF Función de apertura durante
el cierre (conecte los dispositi-
vos de seguridad a los bornes
2-C1) activa; (si no se utiliza,
coloque el dip en ON);
8 ON Función del test de seguridad
para el control del funciona-
miento de las fotocélulas (pág.
6) activa; (8 OFF desactivada).
9 OFF Encoder activo para la ges-
tión de las desaceleraciones
durante la apertura y el cierre
en el caso de detección de
obstáculos (9 ON desactivada);
10 No utilizado