Do you have a question about the CAME S0002 and is the answer not in the manual?
Brand | CAME |
---|---|
Model | S0002 |
Category | Control Unit |
Language | English |
Buttons used for programming and memorizing codes on the control card.
LED indicator for signaling status or events on the control card.
Dip-switch for selecting various operational functions of the control card.
Connection terminals for wiring input/output signals and power supply.
Guidance on installing the control card box outside the CAME control panel when internal installation is not feasible.
Connect terminals 'C' and 'N.O.' to 2-3 for 'opening only' operation.
Connect terminals 'N.O.' and 'C' to 2-7 for 'open-close with reversal' operation.
Respect polarity (+/-) when powering the unit with DC supply.
Enter desired code within 10 seconds per digit for successful programming.
Press the CH1 data storage button to memorize the code for the OUT1 output.
Repeat procedure for OUT2 with a different code, saving with CH2 button for a 1-second impulse.
Enter the memorized code; system allows up to 5 errors before a 1-minute shutdown.
Hold the 'E' pushbutton for the desired duration for monostable operation.
Selects the monostable operating mode for the OUT1 output.
Selects the bistable operating mode for the OUT1 output.
Configures the output to provide a one-second impulse.
Up to five selectors can be connected in parallel to the decoder.