Output:
SDI-12 Version 1.3 compliant
Operating temperature range:
–50 to 60 °C (except barometer and RH, which are –40 to 60 °C)
Supply voltage:
3.6 to 15.0 VDC (continuous)
Power consumption
Quiescent:
0.3 mA
Maximum peak current:
33 mA
Average:
1.0 mA (using R7! every 10 s),
0.4 mA (using R7! every 60 s or slower)
Digitalvoltage(logichigh):
2.8 V (minimum), 3.0 V (typical), 5.5 V (maximum)
Digital voltage (logic low):
–0.3 V (minimum), 0.0 V (typical), 0.8 V (maximum)
Measurement duration:
110 ms (typical), 3000 ms (maximum)
Diameter (includes rain gage
filter):
10 cm (4 in)
Height:
34 cm (13.4 in)
Application of Council
Directive
2011/65/EU:
Restrictions of Substances Directive (RoHs2)
2014/30/EU:
Electromagnetic Compatibility Directive (EMC)
Standards to which conformity
is declared
EN 61326-1:2013:
Electrical equipment for measurement, control and laboratory
use—EMC requirements—for use in industrial locations
EN 50581:2012:
Technical documentation for the assessment of electrical and
electronic product with respect to the restriction of hazardous
substances
EU Declaration of Conformity:
View at:
www.campbellsci.com/climavue-50
Power line slew rate:
1.0 V/ms (use an oscilloscope to measure the voltage at the
power input to the sensor as it is turned on to ensure it is
supplying 1 V per millisecond or faster)
ClimaVUE 50 Compact Digital Weather Sensor 12