Table 8-1: Standard ClimaVUE 50 SDI-12 commands
SDI-12 command
(a is the sensor
address)
Values returned Units
aM1!
1
1. Tilt North(+)/South(–) orientation
2. Tilt West(+)/East(–) orientation
3. Compass heading (disabled)
°
°
°
aM3!
1
1. Strike distance
2. Relative humidity
3. Humidity sensor temperature
4. Tilt North(+)/South(–) orientation
5. Tilt West(+)/East(–) orientation
6. Compass heading (disabled)
7. North wind speed
8. East wind speed
9. Wind speed max. 10 s gust
km
fraction (0 to 1)
°C
°
°
°
m s
-1
m s
-1
m s
-1
ClimaVUE 50 Compact Digital Weather Sensor 23