219
ONVIF warning (RTP)
R101 RTP session timeout [notice]
R102 Information acquisition failure (RTP
payload size) [notice]
R102 Information acquisition failure (IP
address) [notice]
R103 RTSP authentication failure [notice]
R107 RTSP connection failure [notice]
Notification log
System notification
S001 System started [info]
S002 System settings changed [info]
S010 Event service started [info]
S011 Event service shut down [info]
S012 External device service started [info]
S013 External device service shut down
[info]
S014 Timer service started [info]
S015 Timer service shut down [info]
Description session timeout: session ID=%1
(R101)
%1 Session ID
Meaning RTP session has timed out.
Description cannot get parameter:
RTP_payload_size (R102)
Meaning Information acquisition has failed (RTP
payload size).
Description cannot get parameter: IP_address
(R102)
Meaning Information acquisition has failed (IP
address).
Description RTSP authorization error (R103)
Meaning RTSP authentication has failed.
Description RTSP Error: error_code=%d: Service
Unavailable (R107)
%d 400: Value used for RTSP is invalid.
401: RTSP authentication failure or
missing valid authentication
information.
457: Playback time for RTSP is invalid.
501: An invalid RTSP option was used.
503: Failure to offer service, due to
insufficient resources.
The number of maximum RTP
sessions, has passed the limit.
Meaning RTSP connection has failed.
Description starting paramd (S001)
Meaning Parameter management module
started.
Description Updated system settings. (S002)
Meaning Settings not requiring rebooting were
changed.
Description starting event (S010)
Meaning The event service was started.
Description shutdown event (S011)
Meaning The event service was shut down.
Description starting extio (S012)
Meaning The external device input/output
service was started.
Description shutdown extio (S013)
Meaning The external device input/output
service was shut down.
Description starting timer (S014)
Meaning The timer service was started.
Description shutdown timer (S015)
Meaning The timer service was shut down.

Table of Contents

Other manuals for Canon VB-H651VE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Canon VB-H651VE and is the answer not in the manual?

Canon VB-H651VE Specifications

General IconGeneral
Resolution1920 x 1080
Image Sensor1/2.8-inch CMOS
ApertureF1.6
Shutter Speed1/30 sec to 1/10, 000 sec
Day/NightYes
Video CompressionH.264, MJPEG
Frame RateUp to 30 fps
Audio SupportTwo-way audio (input/output)
Network InterfaceRJ45 (10Base-T/100Base-TX)
Power SupplyPoE (Power over Ethernet)
Operating Temperature-10°C to 50°C