10 Instruction manual CE902SS/CE902WH Please keep this instruction manual for future reference
OPENING THE PANEL
It is possible to open the steel panels, which
cover the grease filters, by pulling the side
of them gently as shown in Fig.1. To achieve
the complete opening of the panels, you
need to release the safety chains by using the
appropriate spring catches.
To work correctly, it is recommended to install
the product at a maximum distance of 2000-
2100mm, from the floor level.
Before proceeding with the installation of the
appliance, check that all the components are not
damaged, otherwise please contact your retailer and do not continue with the installation.
Use an air outlet pipe with a maximum length of no more than 5 metres. Reduce the number of
bends in the duct as each bend reduces the suction efficiency equivalent to 1 linear meter.
(E.g. If 2 90° bends are used, the length of the duct should not exceed 3 meters in length).
Avoid abrupt changes of direction.
Use a duct with a diameter of 150mm constant over the entire length.
Use a duct of recognised and approved material.
For more information on venting, please see our ‘Extraction & Ventilation guide’ available at
www.caple.co.uk