EasyManua.ls Logo

Cardinal 200 Series - User Manual

Cardinal 200 Series
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
200 SERIES
WEIGHT INDICATING INSTRUMENT
MODELS 200, 205 and 210
TECHNICAL and OPERATION MANUAL
8200-M024-O1 Rev D
PO BOX 151 WEBB CITY, MO 64870
Printed in USA
04/01
PH
(
417
)
673-4631 FAX
(
417
)
673-5001
http://www.cardinalscale.com

Questions and Answers

  • A
    angela86Aug 20, 2025
    What to do if Cardinal 200 display shows oCAP (over Capacity)?
    • J
      Jeremiah MuellerAug 20, 2025
      If the Cardinal Accessories display shows 'oCAP', it means the load on the scale exceeds the scale capacity plus nine divisions. You should remove the excess load from the scale platform. This may also indicate miscalibration.
  • A
    Andrea Sexton DDSAug 22, 2025
    What does ErrAh (Error Analog high) mean on Cardinal 200, and how to fix it?
    • M
      marcperezAug 22, 2025
      If you see 'ErrAh' on your Cardinal Accessories, it indicates that the load cell input is above the range of the indicator. Check for improper load cell wiring, excessive load, and ensure the output is between 1 to 40mV. If the issue persists, it may be due to load cell or circuit failure.
  • J
    jturnerAug 25, 2025
    What does ErrAL (Error Analog Low) mean on Cardinal 200 Accessories, and how do I resolve it?
    • K
      Kathryn PerryAug 25, 2025
      If your Cardinal Accessories display shows 'ErrAL', it means the load cell input is below the range of the indicator. Check for improper load cell wiring and ensure the output is between 1 to 40mV. If the issue continues, it could be a load cell or circuit failure.
  • A
    Andrew HendersonAug 26, 2025
    How to resolve incorrect weight displayed on Cardinal 200 Accessories?
    • F
      forddianaAug 26, 2025
      If your Cardinal Accessories are displaying an incorrect weight, ensure the indicator has been calibrated. Also, check that the scale platform isn't touching any adjacent objects and inspect the load cell connector wiring. If you're using four-wire load cells, make sure the sense lead jumpers (J6 & J9) are installed. Finally, verify that proper operating procedures have been followed.
  • K
    Katrina SmithAug 28, 2025
    What does '-oF- (overflow)' mean on Cardinal 200 and how can I fix it?
    • M
      Michael DavisAug 28, 2025
      If your Cardinal Accessories displays '-oF-', it means the indicator is attempting to display a positive number greater than six digits in length or a negative number of more than five digits. Return to Gross Weight mode and review the Tare value. This issue may also indicate miscalibration.
  • P
    Philip VillarrealAug 29, 2025
    How to fix UnStb (Unstable) message on Cardinal Accessories?
    • S
      Stephanie PetersonAug 30, 2025
      If your Cardinal Accessories displays 'UnStb', it means there's motion present when trying to perform a print function. Wait for a stable weight display, indicated by the 'STABLE' annunciator being on, before proceeding.
  • A
    Alicia MillerAug 31, 2025
    How to resolve E[2]PROM checksum failure in Cardinal 200?
    • R
      rhonda08Sep 1, 2025
      If you encounter an 'E[2]PROM checksum failure' message on your Cardinal Accessories, recalibrate the device using a calibrated test weight.
  • A
    Anthony ByrdSep 2, 2025
    What does EEFAiL (External EEPROM memory write/read failure) mean for Cardinal Accessories?
    • N
      Nina MillerSep 2, 2025
      If your Cardinal Accessories displays 'EEFAiL', it indicates an external EEPROM memory write/read failure. Press any key to continue. No other action is necessary if ID storage is not used.
  • E
    Eric FrancisSep 4, 2025
    What does EE Err (External EEPROM memory retention error) mean on Cardinal Accessories?
    • S
      Stephanie ScottSep 4, 2025
      If your Cardinal Accessories displays 'EE Err', it indicates an external EEPROM memory retention error. Press any key to continue. No other action is necessary if ID storage is not used.
  • G
    guzmanrebeccaSep 6, 2025
    What does iiCErr (IIC bus failure) mean on Cardinal 200?
    • J
      Johnny JohnsonSep 6, 2025
      If your Cardinal Accessories displays 'iiCErr', it indicates an IIC bus failure. Press any key to continue.