21
SETUP AND CALIBRATION, Cont.
Unit1= (Weighing Unit 1)
Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric keys enter the new setting, then press
the
ENTER
key to save it. Allowable values are:
0 = none 4 = oz (ounces)
1= tn (tons) 5 = kg (kilograms)
2= g (grams) 6 = tonnes (metric tons)
3 = lb (pounds) 7 = lb/oz (pounds/ounces)
Int= (Interval Setting)
Press the
ENTER
key to show the current value.
If LFt = 1 (Legal For Trade = YES), using the numeric keys enter the new setting, then press the
ENTER
key to save it. Allowable values are: 1, 2, 5, 10 , 20 or 50.
If LFt=0 (Legal For Trade = NO), using the numeric keys enter the new setting, then press the
ENTER
key to save it. Allowable values are: 1 through 99.
In either case, if the setting displayed is acceptable, press the
ENTER
key again it.
dPP= (Decimal Point Setting)
Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric keys enter the new setting, then press
the
ENTER
key to save it. Allowable values are: 0, 1, 2 or 3.
0 = XXXXXX 2 = XXXX
.
XX
1= XXXXX
.
X 3 = XXX
.
XXX
CAP= (Capacity)
Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric keys enter the new setting, then press
the
ENTER
key to save it. Allowable values are: 1 through 999,999.
NOTE!
Capacity cannot exceed 999,999.
Unit2= (Weighing Unit 2)
Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric keys enter the new setting, then press
the
ENTER
key to save it. Allowable values are:
0 = none 4 = oz (ounces)
1= tn (tons) 5 = kg (kilograms)
2= g (grams) 6 = tonnes (metric tons)
3 = lb (pounds) 7 = lb/oz (pounds/ounces)
NOTE!
Not all units are available. Dependent upon selection made for UNIT1.
trA= (Zero Trackin Range)
Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric keys enter the new setting, then press
the
ENTER
key to save it. Allowable values are: 0 (disables Zero Tracking), .5, or 1 through 9.
trL= (4% Zero Range)
Press the
ENTER
key to show the current value. If the setting displayed is acceptable, press the
ENTER
key again to save it. Otherwise, using the numeric keys,
0/NO
or
1/YES
, enter the new
setting, then press the
ENTER
key to save it.
Trl = 1 (Yes) trl = 0 (No)
4% of scale capacity Full capacity (no limit)

Other manuals for Cardinal 200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cardinal 200 Series and is the answer not in the manual?

Cardinal 200 Series Specifications

General IconGeneral
BrandCardinal
Model200 Series
CategoryAccessories
LanguageEnglish

Related product manuals