EasyManua.ls Logo

Cardinal 225 - Setting 5-Zone Presets

Cardinal 225
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8200-M564-O1 y 225 Check Weigher
Page 11
OPERATION, CONT.
Enter the Preset values for a 5 zone Checkweigher using the following procedure:
1. With the indicator in the Gross Weight mode (Gross annunciator, G on the display), press
the PRESET key.
2. The display will show UNDER=XXXXXX, where XXXXXX is the current value of the
under preset.
3. If the displayed value is acceptable, press the ENTER key to save it. Otherwise use the
numeric keys to enter a new value and then press the ENTER key to save it.
4. The display will show LOW OK=XXXXXX, where XXXXXX is the current value of the
low accept preset.
5. If the displayed value is acceptable, press the ENTER key to save it. Otherwise use the
numeric keys to enter a new value and then press the ENTER key to save it. Note that
this value must be greater than the under value.
6. The display will show HIGH OK=XXXXXX, where XXXXXX is the current value of the
high accept preset.
7. If the displayed value is acceptable, press the ENTER key to save it. Otherwise use the
numeric keys to enter a new value and then press the ENTER key to save it. Note that
this value must be greater than the under value, but less than the over value.
8. The display will show OVER=XXXXXX, where XXXXXX is the current value of the over
preset
9. If the displayed value is acceptable, press the ENTER key to save it. Otherwise use the
numeric keys to enter a new value and then press the ENTER key to save it. Note that
the over value must be greater than the high accept value.
7. After the over preset value is entered, the 225 will return to normal operation.
NOTE! Remember that the check weigher function operates on the absolute value of
the weight ignoring the polarity.