8200-M564-O1 y 225 Check Weigher
Page 10
OPERATION
If the check weigher feature is configured for a 3-zone weight comparison, the indicator will
make a comparison of the displayed weight with a high (OVER) and low (UNDER) preset
value. The results of that comparison will be indicated as UNDER, ACCEPT, or OVER.
If the check weigher feature is configured for the 5-zone weight comparison, the indicator will
make a comparison of the displayed weight with the UNDER, LOW OK, HIGH OK, and OVER
preset values. The results of this comparison will be indicated as UNDER, UNDER ACCEPT,
ACCEPT, ACCEPT OVER, or OVER.
RELAY CONTROL OUTPUTS
OUTPUTS=3
Low State before cutoff (Relay* Open)
PWC1 UNDER
PWC2 ACCEPT
PWC3 OVER
OUTPUTS=5
Low State before cutoff (Relay* Open)
PWC1 UNDER
PWC2 UNDER ACCEPT
PWC3 ACCEPT
PWC4 ACCEPT OVER
PWC5 OVER
Enter the Preset values for a 3 zone Check Weigher using the following procedure:
1. With the indicator in the Gross or Net Weight mode, press the PRESET key.
2. The display will show UNDER=XXXXXX, where XXXXXX is the current value of the
under preset.
3. If the displayed value is acceptable, press the ENTER key to save it. Otherwise use the
numeric keys to enter a new value and then press the ENTER key to save it.
4. The display will show OVER=XXXXXX where XXXXXX is the current value of the over
preset
5. If the displayed value is acceptable, press the ENTER key to save it. Otherwise use the
numeric keys to enter a new value and then press the ENTER key to save it. Note that
the over value must be greater than the under value.
6. After the over preset value is entered, the 225 will return to normal operation.