SETUP, CONT.
OUTPUTS=3
If the check weigher feature is configured for a three-zone weight comparison,
(OUTPUTS=3), the indicator will make a comparison of the displayed weight with a
high and low preset value. The results of that comparison will be indicated as Over,
Under or Accept.
OUTPUTS=3
Low State before cutoff (Relay
¾
Open)
PWC1 UNDER
PWC2 ACCEPT
PWC3 OVER
OUTPUTS=5
If the check weigher feature is configured for the five-zone weight comparison,
OUTPUTS=5, the indicator will make a comparison of the displayed weight with the
high, high-accept, low-accept and low preset values. The results of this comparison will
be indicated as Over, High-Accept, Accept, Low-Accept or Under.
OUTPUTS=5
Low State before cutoff (Relay
¾
Open)
PWC1 UNDER
PWC2 UNDER ACCEPT
PWC3 ACCEPT
PWC4 ACCEPT OVER
PWC5 OVER
¾
The relay state is based on using Cardinal Scale relays (p/n 6850-1013). If using relays
other than those supplied by Cardinal Scale, refer to the relay manufacturers specifications.
NOTE! When power to the indicator is lost, the output returns to a Low State condition.
2.AUTO PRINT=XXX – AUTOMATIC PRINT
The automatic print feature will cause an optional printer to print when the weight is in the
ACCEPT range and STABLE. STABLE is defined by the STABLE= and STBL CNT=
parameters settings in the SCALE 1 SETUP MENU #1.
The display will show AUTO PRINT=XXX where XXX is the current value. If the setting
displayed is acceptable, continue to the next section.
To change the current setting, press the 2 key and then the ENTER key.
AUTO PRNT=XXX will be displayed at the bottom of the display. Using the YES or NO
key, select the new setting and then press the ENTER key to save it.
AUTO PRNT=YES
Automatic Print Enabled
AUTO PRNT=NO
Automatic Print Disabled