8200-M564-O1 y 225 Check Weigher
Page 8
SETUP
Check Weigher (Mode of Operation = 4)
When selected, the Check Weigher will compare the displayed weight with preset values and
display the results as under, accept, or over. The checkweighing operation features are
selected in the Check Weigher Menu. To access the setup menus:
1. Press the SHIFT key and then the RED SQUARE navigation key.
2. The display will change to show the SETUP/REVIEW MENU.
3. Press the 1 key and then the ENTER key.
4. The display will change to show SETUP MENU #1.
With SETUP MENU #1 displayed the current setting for the 10. MODE OF OP=X
parameter will be shown. Press the 1 and 0 keys and then the ENTER key. The display will
change to show the Mode Of Operation Menu. Press the 4 key and then the ENTER
key to select 4. Check Weigher. The display will change to show the
Check Weigher Menu.
The Check Weigher Menu shows the selections for the Check Weigher setup parameters.
Check Weigher Menu
1. OUTPUTS=X
2. AUTO PRINT=XXX
Enter Selection: X EXIT
1. OUTPUTS=X – NUMBER OF CHECK WEIGHER OUTPUTS
The display will show OUTPUTS=X, where X is the current value. If the setting displayed
is acceptable, continue to 2. AUTO PRINT=XXX.
To change the current setting, press the 1 key and then the ENTER key. OUTPUTS=X will
be displayed at the bottom of the display. Using the numeric keys, enter the new setting
and then press the ENTER key to save it. Allowable values are 3 or 5.
When OUTPUTS=3 is selected, the check weigher will compare the displayed weight with
either high and low preset values. When OUTPUTS=5 is selected, the check weigher will
compare the displayed weight with high, high-accept, low-accept and low preset values.