Instruction manual
™
70 Maple Street East Longmeadow, MA 01028
Ph 413-525-7700 Fx 413-525-8306
Carlin Combustion Technology, Inc.
TECH SUPPORT 800-989-2275
carlincombustion.com
© Copyright 2004 — Carlin Combustion Technology, Inc.
Installer/servicer — Except where specifically stated other-
wise, this manual must be used only by a qualified service
technician. Failure to comply with this or other requirements
in this manual could result in severe personal injury, death or
substantial property damage.
User — Refer only to User care and maintenance on back
page for information regarding operation of this burner. The
burner Instruction Manual is intended only for your service
technician. The burner and heat exchanger must be inspected
and started at least annually by your service technician.
Ratings
Input: 201CRD ........................................2.50 to 5.00 GPH
301CRD (3¼’’ air cone) ............ 3.00 to 6.00 GPH
301CRD (3½’’ air cone) ............ 4.00 to 7.00 GPH
Fuels: U.S. .................................... No. 1 or No. 2 Fuel oil
Canada ....... No. 1 Stove oil or No. 2 Heating oil
Fuel unit: .....................................................................Suntec
........................... 100 to 150 PSIG nozzle pressure
...........................................Factory set at 150 PSIG
Electrical: Power ................................... 120V/60 Hz/1-Phase
Motor ...................Carlin PSC, 1/4 HP, 3450 RPM
Total current at 120V/60 Hz/1-Phase:
201CRD ............................Approx. 3.2 amps
301CRD ............................Approx. 3.2 amps
Ignition: . Carlin Model 41000 electronic — 14,000 volts
Control: .................................. U.L. primary safety control
Agencies: ..................................UL Listed (US and Canada)