EasyManua.ls Logo

Carrier 33CS420-01 - Calibrating the Temperature and Humidity Sensors

Carrier 33CS420-01
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
After calibration is complete, press the MODE button to return to
normal operation.
Page 18.3
Calibrating the Temperature and Humidity SensorsCalibrating the Temperature and Humidity Sensors
OFF
I2:00
72
Pm
PRESS
TWICE
FAN
MODE
MODE
Press and hold the MODE
button. While holding the
MODE button, press and hold
the FAN button for 5 seconds.
All icons will appear on the
display.
Under normal circumstances it will not be necessary to adjust the
calibration of the temperature and humidity sensors. If calibration is
required, please contact a trained HVAC technician to correctly
perform the following procedure.
Place the thermostat in the
OFF mode.
Press the UP and DOWN buttons
at the same time twice. The
thermostat temperature will be
displayed and may be calibrated
using the UP or DOWN buttons.
CALIBRATE
CALIBRATE
THERMOSTAT SENSOR
Su
18
MODE
Press the MODE button once. The
relative humidity at the thermostat will be
displayed and may be calibrated using the
UP or DOWN buttons.
HUMIDITY SENSOR
AUTO
OFFON
Override
Unoccupied
Am
I8:88
SuMoTuWeThFrSa
Pm
AUXHEAT
COOL
FanOn
Service Filter
UV Light
Program On
StartStop
DeHumidify
I88
Setup
Outside
88
L O
H I
88
Carrier

Table of Contents

Other manuals for Carrier 33CS420-01

Related product manuals