Type | Non-Programmable |
---|---|
Stages | 1 Heat/1 Cool |
Programmability | Non-Programmable |
Display | Digital |
Fan Control | Auto/On |
Hold Feature | Yes |
Filter Change Alert | No |
Battery Backup | No |
Weight | 0.5 lbs |
Power Source | 24VAC |
Temperature Range | 45°F to 90°F (7°C to 32°C) |
Guides users on choosing between heating, cooling, or auto modes.
Brief introduction to the fan button's functionality.
Describes the function and location of buttons on the thermostat's front panel.
Explains the various icons and information displayed on the thermostat screen.
Details how to configure the thermostat for automatic or manual operating modes.
Guides users on choosing the correct operating mode (Heat, Cool, Auto, Off).
Explains how to set the desired temperature for heating and cooling.
Instructions on how to view readings from the optional outside temperature sensor.
Instructions on how to view indoor humidity readings using the Humidity Module.
Explains how to override the thermostat's normal operation mode.
Details how to use the fan button for manual or automatic fan control.
Explains the smart fan feature for energy efficiency.
How to configure delays for fan operation after cooling cycles.
Instructions for enabling or disabling the thermostat's backlight.
How to set temperature display between Fahrenheit and Celsius.
Steps to prevent unauthorized access by locking or unlocking the keypad.
How to set security levels to limit thermostat adjustments.
Instructions for installing the optional humidity module.
How to configure jumpers for humidification control.
Steps to set the desired humidity level for operation.
How to set jumpers for dehumidification control.
Steps to set the desired dehumidification level.
How to use the AC for dehumidification.
Explains the function and programming of the DEHUM terminal.
How to check the hours the thermostat operated in override mode.
How to check the operating hours of the humidifier system.
How to check the operating hours of the UV light system.
How to check heat pump and reversing valve jumper configurations.
How to check the jumper setting for electric heat operation.
Instructions on activating and using the emergency heat feature.
How to set the minimum temperature difference between heat and cool setpoints.
How to limit the number of HVAC cycles per hour.
How to configure deadband settings for multi-stage operation.
How to set when the second stage turns off.
Instructions for installing wired or wireless remote sensors.
How to configure the thermostat to use remote sensor data.
How to enable and use the dry contact feature.
How to set the polarity for the dry contact (NO/NC).
How to program the dry contact for override or service pan alerts.
How the dry contact forces override setpoints.
Explains the random start delay feature.
How to configure and reset the fan run-time alert.
How to configure and reset the UV light run-time alert.
How to configure and reset the humidifier run-time alert.
How to set jumpers for MISC outputs to control various functions.
Details the functions assigned to different jumper configurations.
Steps to return all thermostat settings to their original factory defaults.
Procedure for adjusting the accuracy of temperature and humidity sensors.
Details the RJ11 jack for connecting accessories like IR receiver or EZ programmer.
Information about using an IR receiver and remote control.
Information about using the EZ programmer for data storage and transfer.