Page 12.3
Adjusting the Cycles Per HourAdjusting the Cycles Per Hour
Press the HUMIDITY button to leave the Setup screens. If no buttons are 
pressed, the display will leave the setup screens after 30 seconds.
HUMIDITY
Press
(d1, d, 2 - 6)
The Cycles Per Hour setting may limit the number of times per hour 
your HVAC unit may energize.  For example, at a setting of 6 cycles 
per hour the HVAC unit will only be allowed to energize once every 10 
minutes.  The Cycles Per Hour limit may be overridden and reset by 
pressing the UP or DOWN buttons on the thermostat.
 
Cy
6
Setup
 I8
Select the cycles per
hour limit.
d=cycles per hour
  limit defeated.
d1=d + defeat 5 min.
  compressor lockout.
Note: Press the MODE 
button momentarily 
to move through the 
setup screens.  Press 
and hold the MODE 
button to move back- 
wards through the 
setup screens.
12
HUMIDITY
MODE
MODE
Press the MODE button.  While holding 
the MODE, press the HUMIDITY button 
to enter Setup screens.
Press the MODE button repeatedly 
until this setup screen appears.