6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1 Reactor L = 10mH, 16A
2 Outdoor fan motor DC140V, 43W
3 Suction temp. sensor (TS sensor)
10k (25°C)
4 Discharge temp. sensor (TD sensor)
62k (20°C)
5 Outside air temp. sensor (TO sensor)
10k (25°C)
6 Heat exchanger temp. sensor (TE sensor)
10k (25°C)
7 Terminal block
(6P) 20A, AC250V
9 COIL FOR P.M.V. DC12V
10 Coil for 4-way valve AC220-240V
CAM-MD12TF-10
STF
Compressor 3-phases 4-poles
1100W
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA130A1F-27F
DA150A1F-20F
Parts name Model name Rating
CH-57
ICF-140-43-4R
No.
Fan motor
(for indoor)
2 Room temp. sensor (TA-sensor)
10k
at 25°C
3 Heat exchanger temp. sensor (TC-sensor)
10k at 25°C
4 Louver motor Output (Rated) 1W, 16 poles, DC12V
( )
(
)
MP24Z3T
ICF-340-30-2B DC-340V, 30W
Parts name
1
SpecificationsType
FILE NO. SVM-10052
38NYV050M2,38NYV050M-A
38NYV060M2,38NYV060M-A