7
2-2. Operation Characteristic Curve
<Coolin
g><Heating>
2-3. Capacity Variation Ratio Accordin
g to Temperature
<Coolin
g><Heating>
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
9.00
10.00
0 102030405060708090100110120
Compressor Speed (RPS)
Current (A)
0.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
9.00
10.00
0 102030405060708090100110120
Compressor Speed (RPS)
Current (A)
50
55
60
65
70
75
80
85
90
95
100
105
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Outdoor Temperature (
o
C)
Capacity Ratio (%)
Capacity Ratio: 100%=
5.0kW (42NQV050M,42NQV050M-N,42NQV050M-A)
6.0kW (42NQV060M,42NQV060M-N,42NQV060M-A)
Condition
Indoor: DB27
o
C / WB19
o
C
Indoor Air-Flow Volume: High
Pipe Length: 7.5m
0
20
40
60
80
100
120
-15 -10 -5 0 5 10
Outdoor Temperature (
o
C)
Capacity Ratio (%)
Condition
Indoor: DB20
o
C
Indoor Air-Flow Volume: High
Pipe Length: 7.5m
42NQV060M
42NQV060M-N
42NQV060M-A
FILE NO. SVM-10052
42NQV050M
42NQV050M-N
42NQV050M-A
42NQV060M
42NQV060M-N
42NQV060M-A
42NQV050M
42NQV050M-N
42NQV050M-A
42NQV050M
42NQV050M-N
42NQV050M-A
42NQV060M
42NQV060M-N
42NQV060M-A
42NQV060M
42NQV060M-N
42NQV060M-A
42NQV050M
42NQV050M-N
42NQV050M-A
Capacity Ratio: 100%=
5.8kW (42NQV050M,42NQV050M-N,42NQV050M-A)
7.0kW (42NQV060M,42NQV060M-N,42NQV060M-A)