4
SPECIFICATIONS
UNIT SIZE 045--12 070--16 090--16 110--22 135--22
RATINGS AND PERFORMANCE
Input Btuh*
Nonweatherized ICS
All 58CTW; 58CTY Upflow
High 44,000 66,000 88,000 110,000 132,000
Low 29,000 43,500 58,000 72,500 87,000
Input Btuh*
Nonweatherized ICS
All 58CTY Downflow/
Horizontal
High 42,000 63,000 84,000 105,000 126,000
Low 29,000 43,000 58,000 72,500 87,000
Output Capacity (Btuh)
Nonweatherized ICS
All 58CTW; 58CTY Upflow
High 35,000 53,000 71.000 89,000 107,000
Low 23,000 35,000 47,000 59,000 70,000
Output Capacity (Btuh)
Nonweatherized ICS
All 58CTY Downflow/
Horizontal
High 34,000 51,000 68.000 85,000 102,000
Low 23,000 35,000 47,000 59,000 70,000
AFUE† 80.0 80.0 80.0 80.0 80.0
Certified Temperature Rise Range --- ° F C)
High 30-60
( 1 7 --- 3 3 )
25-55
( 1 4 --- 3 0 )
30-60
( 1 7 --- 3 3 )
30-60
( 1 7 --- 3 3 )
40-70
( 2 2 --- 3 9 )
Low 20-50
( 1 1 --- 2 8 )
15-45
( 8 --- 2 5 )
25-55
( 1 4 --- 3 0 )
20-50
( 1 1 --- 2 8 )
25-55
( 1 4 --- 3 0 )
Certified External Static Pressure Heat/Cool 0.10/0.50 0.12/0.50 0.15/0.50 0.20/0.50 0.20/0.50
Airflow CFM‡
Heating High/Low 820/725 1570/1045 1265/1030 1555/1295 1865/1640
Cooling 1175 1685 1770 2230 2290
ELECTRICAL
U n i t V o l t s --- H e r t z --- P h a s e 115-60-1
Operating Voltage Range Min-Max 104-127
Maximum Unit Amps 8.0 9.6 10.2 13.0 13.0
Maximum Wire Length (Measure 1 Way in Ft. (M)) 34 (10.4) 28 (8.5) 27 (8.2) 34 (10.4) 34 (10.4)
Minimum Wire Size 14 12
MaximumFuseorCktBkrSize(Amps)** 15 20
Transformer (24v) 40va
External Control Heating 12va
Power Available Cooling 35va
Air Conditioning Blower Relay Standard
CONTROLS
Limit Control SPST
Heating Blower Control Solid-State Time Operation
Burners (Monoport) 2 3 4 5 6
Gas Connection Size 1/2-in. NPT
GAS CONTROLS
Gas Valve
(Redundant)
Mfr. White-Rodgers
Min. inlet pressure (In. W.C.) 4.5 (Natural Gas)
Max. inlet pressure (In. W.C.) 13.6 (Natural Gas)
Ignition Device Hot Surface
Factory-installed orifice Size 43
BLOWER DATA
Direct-Drive Motor HP (ECM) 1/2 3/4 3/4 1 1
Motor Full Load Amps 6.8 8.4 8.4 10.9 10.9
RPM (Nominal) 1200
Blower Wheel Diameter x Width --- In. (mm) 10 x 6
(254x152)
11 x 8
(279x203)
10 x 10
(254x254)
11 x 11
(279x279)
11 x 11
(279x279)
* Gas input ratings ar e certified for elevations to 2000 ft. (610 M). For elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft. (305M)
above sea l evel. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1---2012 Table F.4 or furn ace installa tion instructions.
Capacity in accordance with U.S. Government DOE test procedures.
Airflow shown is for bottom only return-air suppl y for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table f or other options. A
filter is required for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16 in. (110 mm) wide, high
efficiency media filter.
** Time---delay type is recommended.