HEATING
A
COOLING
58ED,PB
Horizontal
Gas-Fired
Furnaces
American
Gas
Association,
1515
Wilson
Boulevard,
Arlington,
VA
22209.
A
WARNING
The
furnace
cabinet
must
have
an
uninterrupted
or
unbroken
electrical
ground
to
minimize
personal
injury
if
an
electrical
fault
should
occur.
The
unit
must
also
be
electrically
grounded
in
accordance
with
local
codes,
with
the
National
Electrical
Codes
ANSI/NFPA
No.
70-1984
or
the
latest
edition.
Do
not
use
gas
piping
as
an
electrical
ground.
INSTALLATION
Step
1
Select
Location
This
furnace
may
be
located
in
an
attic,
basement
crawl
space,
alcove
or
suspended
from
the
ceiling
of
a
utility
room
or
basement.
As
shown
in
Table
3,
the
minimum
clearances,
or
greater,
must
be
provided
between
the
furnace
and
adjacent
construction.
A
WARNING
Failure
to
comply
with
all
the
recommended
clear¬
ances
will
result
in
a
fire
hazard.
If
a
furnace
is
to
be
installed
in
a
residential
garage,
it
must
be
installed
so
the
burners
and
the
ignition
source
are
located
not
less
than
18
in.
above
the
floor
and
the
furnace
must
be
located
or
protected
to
avoid
physical
damage
by
vehicles.
The
furnace
should
be
located
as
close
to
the
chimney
as
possible
in
order
to
keep
vent
connections
as
short
and
direct
as
possible.
The
furnace
should
also
be
located
as
near
to
the
center
of
the
air
distribution
as
possible,
and
should
be
mounted
level.
Since
this
furnace
is
suitable
for
attic
installation,
it
must
not
be
installed
directly
on
carpeting,
tile
or
other
combustible
material.
Line
contact
is
only
permissible
between
lines
formed
by
the
intersection
of
the
furnace
top
and
two
sides
and
the
building
joists,
studs
or
framing.
See
Fig.
2
A
clearance
of
at
least
30
in.
should
be
provided
at
the
front
of
the
furnace
for
combustion
air
and
servicing.
For
attic
installations,
the
passageway
and
service
area
adjacent
to
the
furnace
should
have
a
floor
installed.
The
areas
adjacent
to
the
combustion
air
openings
must
be
covered
with
fireproof
board
or
sheet
metal
extending
a
minimum
of
12
in.
from
the
furnace.
See
Fig.
2.
If
the
furnace
is
to
be
installed
in
a
crawl
space,
consult
local
codes.
Use
of
a
concrete
pad
one
to
2
in.
thick
is
recommended.
If
the
furnace
is
to
be
suspended
from
the
ceiling,
it
is
necessary
to
use
steel
pipe
straps
around
each
end
of
the
furnace.
These
straps
should
be
attached
to
the
furnace
with
sheet
metal
screws
and
bolted
to
the
rafters.
The
furnace
may
also
be
suspended
by
an
angle
iron
frame
bolted
to
the
rafters.
->
Table
2
Blower
Data
(Direct
Drive)
FURNACE
58ED/PB
050
075
100
125
140
SERIES
(15th
Digit
A
C
A
B
C
A
B
C
C
D
B
C
of
Model
No.)
BLOWER
SIZE
(in
)
_
_
DXW
10x4
10x4
10x6
10x6
10x6
10x6
10x8
10x8
10x8
12
x
9
12x9
12
x
12
12x12
MOTOR
HP
(PSC)
%
'A
%
%
A
%
%
A
'4
Vt
%
1
^
%
SPEED
TAP
Lo
Hi
Lo
Hi
Lo
Lo
Hi
Med
Hi
Med
Lo
Hi
Med
Hi
Med
Hi
Med
Hi
Med
Hi
Med
Hi
Med
WIRE
COLOR
Red
Blk
Red
Blk
Red
Red
Blk
Blu
Blk
Blu
Red
Blk
Biu
Blk
Blu
Blk
Blu
Blk
Blu
Blk
Blu
Blk
Blu
BLOWER
RPM
830
1070
760
1080
700
920
1020
790
1060
820
860
990
730
1050
840
1070
820
1000
920
1070
970
980
780
EXTERNAL
STATIC
PRESSURE
(in
wg)
20
50
20
50
20
20
50
20
50
20
20
50
20
50
20
50
20
50
20
50
20
50
20
AIRFLOW
(Cfm)
765
|
930
|
I
7
35
M
I/MJ
11165
|l
130
|
|
995
11260
|
1090
|
1310
11290
1090
|
1530
[
1360
|
|
2010
|
1860
1
2115
|
1810
12100
|
1930
|
2350
|
2100
A
WARNING
When
operating
furnace
in
heating
mode,
thestatic
pressure
and
the
temperature
rise
(outlet
air
temperature
minus
room
temperature)
must
be
within
those
limits
specified
on
the
AGA
rating
plate.
Manufacturer
reserves
the
right
to
discontinue,
or
change
at
any
time,
specifications
or
designs
without
notice
and
without
incurring
obligations.
Book
II
14
PC
101
Catalog
No
535-834
Printed
in
U
S
A
Form
58ED.PB-1SI
Pg
2
6-85
Replaces:
58PB-1
SI
Tab
l6a
18a
For
replacement
items
use
Carrier
Specified
Parts

Related product manuals