Carrier 58ED - Masonry Chimney; TYPE B-L VENT; Attic Installation; Step 6 - Connect Gas Piping

Carrier 58ED
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HEATING
A
COOLING
58ED,PB
Horizontal
Gas-Fired
Furnaces
MASONRY
CHIMNEY
This
furnace
can
be
vented
into
an
existing
masonry
chimney.
Normal
connections
to
a
chimney
are
made
using
single
wall
pipe;
however,
single
wall
pipe
is
not
approved
to
pass
through
any
attic,
inside
wall
or
concealed
space
or
through
any
floor.
For
further
information,
consult
venting
section
of
National
Fuel
Gas
Code.
TYPE
B-l
VENT
The
furnace
is
also
approved
for
use
with
a
Type
B-l
vent
that
terminates
through
the
roof
(horizontal
venting
through
an
outside
wall
is
not
approved).
The
vent
must
be
terminated
with
a
listed
cap
or
roof
assembly.
This
venting
must
be
installed
in
accordance
with
the
vent
manufacturer’s
instructions
and
be
in
accordance
with
all
local
codes.
ATTIC
INSTALLATION
Atticand/or
National
Fuel
Gas
installations
require
the
use
of
Type
B
orType
L
vent
material
The
following
requirements
are
provided
for
venting
system:
1.
Ensure
the
chimney
flue
is
clear
of
any
dirt
or
debris.
2.
Ensure
the
chimney
is
not
serving
an
open
fireplace.
3.
Never
reduce
the
pipe
size
below
the
outlet
size
of
the
furnace.
GAS
SUPPLY
NOTE:
LOCATE
MANUAL
SHUTOFF
VALVE
AS
REQUIRED
BY
THE
LOCAL
AUTHORITY
OR
CODE
IN
THE
ABSENCE
OF
SUCH
A
CODE,
LOCATE
THE
GAS
MANUAL
MAIN
SHUTOFF
VALVE
AT
5
j
FT
SUPPLY
GAS
PIPE
LAYOUT
AFTER
REVERSING
COMPONENTS
Fig.
4
Gas
Pipe
Layout
4.
All
pipe
should
be
supported
using
the
proper
clamps
and/or
straps
5.
All
horizontal
runs
of
pipe
must
have
an
upward
slope
of
1/4
in.
per
foot.
6.
All
runs
of
pipe
should
be
as
short
as
possible
with
as
few
turns
as
possible.
7.
Seams
must
be
tightly
joined
and
checked
for
leaks.
8
The
flue
pipe
must
not
extend
into
the
chimney,
but
be
flush
with
the
inside
chimney
wall.
9.
The
chimney
or
gas
vent
must
extend
3
ft
above
the
highest
point
where
it
passes
through
a
roof
of
a
building
and
at
least
2
ft
higher
than
any
portion
of
a
building
within
a
horizontal
distance
of
10
feet.
It
shall
also
extend
at
least
5
ft
above
the
highest
connected
equipment
flue
collar.
10
Check
local
codes
for
any
variance.
Step
6
Connect
Gas
Piping
Install
gas
piping
to
provide
a
supply
of
gas
sufficient
to
meet
the
maximum
demand
without
undue
loss
of
pressure
between
the
gas
meter
and
the
furnace.
The
gas
line
to
the
furnace
should
be
a
separate
line
direct
from
the
meter,
unless
the
existing
gas
line
is
of
ample
capacity.
Refer
to
Table
5
for
sizing
gas
piping.
Use
a
joint
compound
(pipe
dope)
resistant
to
the
action
of
liquefied
petroleum
gases
or
to
any
other
chemical
constituents
of
the
gases
to
be
conducted
through
the
piping.
Before
any
system
of
gas
piping
is
finally
put
into
service,
it
should
be
carefully
tested
to
determine
if
it
is
gas
tight.
The
piping
must
withstand
a
pressure
of
6
in.
Hg
for
a
period
of
10
minutes
or
as
required
by
local
authority.
A
WARNING
The
furnace
and
its
individual
shutoff
valve
must
be
disconnected
from
the
gas
supply
system
during
any
pressure
testing
of
that
system
at
test
pressures
in
excess
of
1
/
2
psig.
The
furnace
must
be
isolated
from
the
gas
supply
piping
system
at
pressures
equal
to
or
less
than
1
/2
psig.
The
recommended
method
for
installing
the
gas
piping
to
the
furnace
is
shown
in
Fig.
4.
Also
shown
is
correct
piping
if
the
gas
valve
and
controls
have
been
reversed
in
the
field.
Table
5
Gas
Pipe
Sizing
(Cu
Ft
of
Gas
per
Hour)*
LENGTH
OF
PIPE
(ft)
DIAMETER
OF
PIPE
IPS
(in.)
%
%
1
Vk
Vk
10
132
278
520
1050
1600
20
92
190
350
730
1100
30
73
152
285
590
890
40
63
130
245
500
760
50
115
215
440
670
75
93
175
360
545
100
79
150
305
460
150
_I
64
120
250
380
‘Based
on
gas
pressures
of
0
5
psig
or
less
and
pressure
drop
of
0
3
in
wg
and
0
60
specific
gravity
gas
Manufacturer
reserves
the
right
to
discontinue,
or
change
at
any
time,
specifications
or
designs
without
notice
and
without
incurring
obligations.
Book|1
|4
PC
101
Catalog
No
535-834
PrintedinUSA
Form
58ED.PB-1SI
Pg5
6-85
Replaces.
58PB-1
SI
Jab
l6a
1
8
a
For
replacement
items
use
Carrier
Specified
Paris

Related product manuals