4. To operate furnace, follow procedures on the lighting instruc-
tions label on the furnace.
5. With furnace operating, set thermostat below room tempera-
ture and observe that the furnace goes off. Set thermostat
above room temperature and observe that the furnace restarts.
ADJUSTMENTS
1. Set gas input rate.
There are 2 methods of adjusting the gas input rate. The
preferred method is by using Table 6 and following instruc-
tions in item a. The second is by clocking the gas meter and
following instructions in item b.
The gas valve regulator has been nominally set at 3.5-in. wc
for natural gas. When adjusting input rate, do not set manifold
pressure above 3.8-in. wc or below 3.2-in. wc.
a. Check gas input rate using Table 6.
(1.) Obtain average yearly heat value for local gas supply.
(2.) Obtain average yearly specific gravity for local gas
supply.
(3.) Verify furnace model. Table 6 can only be used for
model 58GFA Furnaces.
(4.) Check and verify orifice size in furnace. NEVER
ASSUME THE ORIFICE SIZE. ALWAYS CHECK
AND VERIFY.
Table 6—Model 58GFA Orifice Size and Manifold Pressure for Correct Input Rate
(Tabulated Data Based on Altitude Up to 2000 Ft and 21,000 Btuh Per Burner)
GAS HEAT VALUE
(BTU/CU FT)
SPECIFIC GRAVITY OF NATURAL GAS
0.54 0.56 0.58 0.60 0.62 0.64 0.66 0.68 0.70 0.72
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
Orf
No.
Mnfld
Press.
860
43
3.8
42
-
3.2
42
3.3
42
3.5
41
42
3.2
3.6
41
42
3.3
3.7
40
41
42
3.2
3.4
3.8
40
41
3.3
3.5
40
41
3.3
3.6
39
40
41
3.2
3.4
3.7
875
43
3.7
43
3.8
42
3.2
42
3.3
42
3.4
41
42
3.2
3.6
41
42
3.3
3.7
41
42
3.4
3.8
40
41
3.2
3.5
40
41
3.3
3.6
890
43
3.5
43
3.7
43
3.8
42
3.2
42
3.3
42
3.4
41
42
3.2
3.5
41
42
3.3
3.7
41
42
3.4
3.8
40
41
3.2
3.5
905
43
3.4
43
3.6
43
3.7
43
3.8
42
3.2
42
3.3
42
3.4
41
42
3.2
3.5
41
42
3.3
3.6
41
42
3.4
3.7
920
43
44
3.3
3.8
43
3.4
43
3.6
43
3.7
43
3.8
42
3.2
42
3.3
42
3.4
41
42
3.2
3.5
41
42
3.3
3.6
935
43
44
3.2
3.7
43
44
3.3
3.8
43
3.4
43
3.6
43
3.7
43
3.8
42
3.2
42
3.3
42
3.4
41
42
3.2
3.5
950
44
3.6
43
44
3.2
3.7
43
44
3.3
3.8
43
3.5
43
3.6
43
3.7
43
3.8
42
3.2
42
3.3
42
3.4
965
44
3.4
44
3.6
43
44
3.2
3.7
43
44
3.3
3.8
43
3.5
43
3.6
43
3.7
43
3.8
42
3.2
42
3.3
-
980
44
3.3
44
3.5
44
3.6
43
44
3.2
3.7
43
44
3.4
3.8
43
3.5
43
3.6
43
3.7
43
3.8
42
3.2
995
44
3.2
44
3.4
44
3.5
44
3.6
43
44
3.3
3.7
43
44
3.4
3.8
43
3.5
43
3.6
43
3.7
43
3.8
1010
45
3.8
44
3.3
44
3.4
44
3.5
43
44
3.2
3.6
43
44
3.3
3.7
43
44
3.4
3.8
43
3.5
43
3.6
43
3.7
1025
45
3.7
44
45
3.2
3.8
44
3.3
44
3.4
44
3.5
43
44
3.2
3.6
43
44
3.3
3.7
43
44
3.4
3.8
43
3.5
43
3.6
1040
45
46
3.6
3.8
45
3.7
44
3.2
44
3.3
44
3.4
44
3.5
43
44
3.2
3.6
43
44
3.3
3.7
43
44
3.4
3.8
43
3.5
1055
45
46
3.5
3.7
45
46
3.6
3.8
45
3.8
44
3.2
44
3.3
44
3.4
44
3.5
43
44
3.2
3.6
43
44
3.3
3.7
43
44
3.4
3.8
1070
45
46
3.4
3.6
45
46
3.5
3.7
45
46
3.7
3.8
45
3.8
44
3.2
44
3.3
44
3.4
44
3.5
43
44
3.2
3.6
43
44
3.3
3.7
1085
45
46
3.3
3.5
45
46
3.4
3.6
45
46
3.6
3.7
45
3.7
45
3.8
44
3.2
44
3.3
44
3.4
44
3.5
43
44
3.2
3.6
1100
45
46
47
3.2
3.4
3.8
45
46
3.3
3.5
45
46
3.5
3.6
45
46
3.6
3.8
45
3.7
45
3.8
44
3.2
44
3.3
44
3.4
44
3.5
10

Other manuals for Carrier 58GFA

Related product manuals