12
A05053
17
5
16
"
24
1
2
"
27
9
16
"
TYP
27
5
8
"
29
11
16
"
TYP
30
13
16
"
32
5
8
"
TYP
33
1
4
"
TYP
CONDENSAT E
DRAIN TRAP
LOCATION
(ALTERNATE
UPFLOW)
7
8-IN. DIA
ACCESSORY
POWER ENTRY
7
8-IN. DIA
POWER CONN
CONDENSATE DRAIN
TRAP LOCATION
(DOWNFLOW &
HORIZONTAL LEFT)
26
15
16
"
24
1
2
"
22
5
16
"
2
-IN. COMBUSTION-
AIR CONN
1
2
-IN. DIA
GAS CONN
2
-IN. VENT CONN
1
2-IN. DIA THERMOSTAT
ENTRY
22
11
16
"
SIDE INLET
23
1
4
" TYP
SIDE INLET
1
1
4
"
1" E
INLET
11
16
"
11
16
"
D
13
16
"
13
16
"
OUTLET
A
AIRFLOW
OUTLET
26
15
16
"
28
1
2
"
22
5
16
"
19"
13
16
"
5
8
"
5
16
"
1"
39
7
8
"
22
1
4
" TYP
11
16
"
7
16
"
24
3
16
"
BOTTOM INLET
18
1
4
"
22
11
16
"
CONDENSATE DRAIN
TRAP LOCATION
(DOWNFLOW &
HORIZONTAL RIGHT)
OR ALTERNATE
1
2
-IN. DIA GAS CONN
2-IN. COMBUSTION-
AIR CONN
1
2-IN. DIA
GAS CONN
7
8-IN. DIA
POWER CONN
1
2-IN. DIA
THERMOSTAT ENTRY
2-IN. VENT CONN
DIMPLE LOCATORS
FOR HORIZONTAL
HANGING
14
1
2
"
TYP
SIDE INLET
NOTES: 1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used,
see flex duct manufacturerí s recommendations for equivalent diameters.
2. Minimum return-air opening at furnace:
a. For 800 CFM–16-in. round or 14
1
/
2
x 12-in. rectangle.
b. For 1200 CFM–20-in. round or 14
1
/
2
x 19
1
/
2
-in. rectangle.
c. For 1600 CFM–22-in. round or 14
1
/
2
x 23
1
/
4
-in. rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data
literature for specific use of single side inlets. The use of both side inlets, a
combination of 1 side and the bottom, or the bottom only will ensure adequate
return air openings for airflow requirements above 1800 CFM at 0.5 W.C. ESP.
9
7
16
"
TYP
26
15
16
" TYP
CONDENSAT E
DRAIN LOCATION
(UPFLOW)
30
1
2
"
9
16
"
TYP
CONDENSAT E
DRAIN LOCATION
(UPFLOW)
26
1
4
"
26
1
4
"
DIMENSIONS (In.)
* These dimensions reflect the wider casing for the 96.6% AFUE furnace.
UNIT SIZE A D E
040-14* 24-1/2* 22-7/8* 23*
060-14 17-1/2 15-7/8 16
080-14 21 19-3/8 19-1/2
080-20 21 19-3/8 19-1/2
100-20 21 19-3/8 19-1/2
120-20 24-1/2 22-7/8 23

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 58MVB Series and is the answer not in the manual?

Carrier 58MVB Series Specifications

General IconGeneral
Blower MotorVariable-speed
Gas ValveModulating
Ignition SystemHot Surface Ignition
Fuel TypeNatural gas
Heating Capacity40, 000 to 120, 000 BTU/h
Warranty10-year parts limited warranty upon registration

Related product manuals