Details the location and information found on the unit's nameplate, including model and serial numbers.
Inspect and clean the evaporator coil, checking for fin damage, leaks, and corrosion.
Check the evaporator fan motor and stator for bearing drag, corrosion, and secure mounting.
Inspect the evaporator fan blade for cracking or wear and replace if necessary.
Examine wire harnesses for damage and ensure they are properly secured.
Verify the Defrost Termination Sensor is secure, undamaged, and properly connected.
Inspect and clean the defrost drain cup, gutters, and lines for blockages.
Check the EEV for refrigerant leaks, corrosion, and proper connection to the powerpack.
Ensure the Evaporator Temperature Sensor wire tie is in place and insulation is secure.
Inspect heaters and their brackets for damage and ensure proper positioning and wiring.
Check the Heater Termination Thermostat for proper positioning, damage, and replace if needed.
Verify USDA and communication sockets are clean, dry, and have caps fitted.
Check channels, air baffles, and drains for cleanliness to ensure proper air circulation.
Examine the unit for oil residue and perform leak checks on mechanical joints using an electronic detector.
Perform corrosion maintenance by cleaning, scuffing, and repainting affected surfaces.
Inspect evaporator access panels, seals, and evaporator motor shaft for proper condition and fit.
Check gas cooler fan blade for wear, motor for overheating, and mounting bracket integrity.
Inspect the gas cooler coil for leaks, corrosion, and straighten any damaged fins.
Ensure the HPXV coil is fully snapped down and the coil boot is properly fitted.
Check the O-ring seating and ensure the solenoid coil is fully pressed onto the valve stem.
Inspect pressure relief valves for signs of release indicated by indicator tape.
Check the filter drier for excessive corrosion or physical damage and replace if necessary.
Inspect the water-cooled condenser assembly and water connections for damage or corrosion.
Inspect power cables, plugs, and gaskets for damage, arcing, pitting, or missing locating lugs.
Ensure the electrical control box interior is dry, free of damage, and wiring is secured.
Verify interrogation sockets are secure, free from damage, and have properly tethered caps.
Examine loose wires and harnesses outside the control box for neatness and condition.
Inspect the unit frame for cracks, damage, or missing structural items and repair as needed.