EasyManua.ls Logo

Carrier RG67V/BGEF - Freeze Protection (F.P.); Lock Modes Activation; Silence Function

Carrier RG67V/BGEF
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
09
4. HOW TO USE ADVANCED FUNCTIONS
F. P.
Press this button 2 times during one second under HEAT Mode and setting temperature of 16 °C/60° F.
2
The unit will operate at high fan
speed (while compressor on) with
temperature automatically set to
8 °C/46 °F.
Note:This function is for heat pump air conditioner only.
Press this button 2 times under HEAT Mode and setting temperature of 16 °C/60° F to activate the freeze protection
function. It will help to keep the room above 0 °C/32 °F(freezing point) in severe cold winter. Press On/Off, Sleep,
Mode, Fan and Temp. button while operating will cancel this function.
Lock
Mode 1
Press together button and button at the same time more than 2 seconds to activate Lock Mode 1 function.
2s
Swing
2s
Fix
Lock symbol displays
Enter lock mode 1 by pressing and button at the same time more than 2 seconds. At lock mode 1, all
buttons will not response except press these two buttons again to disable locking.
Lock
Mode 2
Press together TIMER button and X-ECO button at the same time more than 2 seconds to activate lock mode 2
function.
2s
Timer
2s
X-ECO
Lock symbol displays
Enter lock mode 2 by pressing TIMER and X-ECO button at the same time more than 2 seconds. At lock mode 2, all
buttons will not response except press ON/OFF, TEMP UP and DOWN buttons or press these two buttons again to
disable locking.
Silence
Keep pressing Fan button for more than 2 seconds to activate/disable Silence function.
Fan
2s
Due to low frequency operation of compressor, it may result in insufcient cooling and heating capacity. Press ON/
OFF, Mode, Sleep button, turn on F.P.or Self clean function while operating will cancel silence function.(Model
dependent)