9. Continuous Run Operation
In the Continuous Run mode, the diesel engine will run continuously
providing constant air flow and temperature control to the product.
Continuous Run operation is normally used for perishable loads.
After start up, check to see that the Auto Start/Stop mode icon is
not illuminated. If it is not illuminated, the unit is already in Continu-
ous Run mode.
If it is illuminated, press the Auto Start/Stop - Continuous key to tog-
gle the unit into Continuous Run mode (unit will operate continu-
ously after starting). The message “CONT ON” is displayed.
NOTE
Continuous Operation may be tied to the setpoint ranges for
frozen and perishable loads and the Auto Start/Stop - Contin-
uous key may be locked out.
NOTE
The unit will remain in low speed for 10 minutes after engine
start-up when the Continuous Run setpoint is below 10°F (-
12°C).
1 (Icon turned off when Continuous Run mode active)