35 62-12002
20.2 Unit Maintenance Schedule
Maintenance Schedule
Initial Check
Up
Service
A
Service
B
Before running
Report any sign of damage on
vehicle/ body/ refrigeration unit.
OO O O
Check coolant level; report
strength.
OO O O
Write down hour meter diesel and
standby.
OO O O
Visually check the tightness of
fixing bolts/screws, frame,
metalworks including remote
evaporators and heater bracket
when applied.
OO O O
Check software revision. Write it
down.
OO O O
Check exhaust system security
and visually check for signs of
corrosion, including sections
where exhaust insulation is
installed (silent-city units).
OO O O
Visually check vibrasorber LP/HP
and fixations.
OO O O
Visually check - shaftseal + oil level
in compressor.
OO O O
Check routing of electrical wires,
harnesses, fuel lines (repair or
replace if needed), cab command
routine, plug from standby module,
check oil tubes routing and security
Check battery security, lubricate
terminals against corrosion, check
battery cables routine.
OO O O
Check fuel tank straps integrity,
fixing bolts, cap. Drain water from
fuel tank if applicable.
OO O