54 | P a g e
Cooling Fan Optimization (Blower Off Delay)
Once a cooling cycle ends the fan will continue to run for this time period. This is
also known as the blower off delay for cooling. The longer the time, the more
cooling is pulled out of the coil but the warmer r the temperature is at the end of the
cycle. The actual blower off delay will always be the longest of the equipment
setting or the thermostat setting.
Default: 0 seconds
Options: Between 0 and 900 seconds
On Thermostat:
Select Menu > (hold) Service > Installation Settings > Thresholds >
Compressor Configurations > Cooling Fan Optimization