EasyManua.ls Logo

Carrier TP-WEM01 - Standard Dehumidification with FV;FK Fan Coils

Carrier TP-WEM01
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
88 | P a g e
h. Press Enabled and Save
7) Congratulations, the fan coil, air conditioner or heat pump and thermostat will
now work together to bring you all the benefits of Ideal Humidity System®
Technology.
Standard Dehumidification with FV/FK Fan Coils
Enhanced dehumidification is achieved by reducing the blower speed to 80% of the
cooling blower speed during a call for dehumidification. You can also choose to use
Cool to Dehumidify and set the cooling off delay to 0 to prevent re-evaporating water on
the coil after a cooling cycle.
Set Up Standard Dehumidification on an FK/FV Fan Coil
1) ACC+ should be connected to the DH terminal