66 | P a g e
Auxiliary Heat Lockout Temperature (Heat Pumps)
NOTE: An internet connection is required for this feature to operate
properly.
Auxiliary heat will not be used when the outdoor temperature is above this
setting.
The auxiliary heat lockout temperature defines the maximum outdoor
temperature where the thermostat can engage auxiliary heat. For instance,
if the setting is 70
o
F and the outdoor temperature is 75
o
F then the thermostat
will not engage auxiliary heat regardless of demand.
Default: 70
o
F
Options: Between 5
o
F and 80
o
F
On Thermostat:
Select Menu > (hold) Service > Installation Settings > Operating
Thresholds > Auxiliary heat Configuration > Auxiliary Heat Lockout
Temperature