73 | P a g e
Heating Stage 2 Temperature Delta (2 Stage Furnace)
The heating stage 2 temperature delta setting controls the staging for the heating
terminals W1 and W2.
The default setting of 3
o
F prioritizes comfort over efficiency. When set to Auto,
the Carrier control algorithms decide when to stage, prioritizing efficiency over
comfort. In Auto, Carrier control algorithms may not engage high stage for up to
10 minutes after a manual setpoint adjustment.
Default: 3
o
F
Options: Between 1
o
F and 10
o
F or Auto
On Thermostat:
Select Menu > (hold) Service > Installation Settings > Operating
Thresholds > Heat Configuration > Heating Stage 2 Temperature
Delta