EasyManua.ls Logo

Carrier TP-WEM01 - Page 96

Carrier TP-WEM01
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
96 | P a g e
b. Press Yes
c. Press Dehumidifier
NOTE: The DHUM on the furnace board is active in the open state. The ACC+
terminal for dehumidifiers is defaulted to active open. So, no other changes are
necessary. You can double check this setting on the thermostat
Menu > (hold) Service > Installation Settings > Equipment Setup >
Accessory > Dehum Open
3) Complete the Guided Setup installation process.
4) Configure Super Dehumidification. For quick reference, you will take the following
steps:
a. Press and hold the Service icon until the screen changes (about 10 sec)
b. Press Installation settings
c. Press Operating thresholds
d. Scroll down to Variable speed blower and press Variable speed blower
e. Press OK on warning screen
f. Press Super dehumidify
g. Press Enabled and Save
a. Press and hold the Service icon until it changes screens, about 10 sec.

Table of Contents

Other manuals for Carrier TP-WEM01

Related product manuals