EasyManua.ls Logo

Carrier Transport Air Conditioning - 1.7 CONDENSERS; Condenser Function and Location; Condenser Specifications Table

Carrier Transport Air Conditioning
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
T--311
1-- 8
Table 1-5 GEN 5 EVAPORATORS -- VARIABLE SPEED
EVAP. CFM Amps (High Speed) V ariable Speed Weight
EM-1 1500
29.5 @ 12.5 V olts
30.1 @ 13.5 V olts
16.0 @ 24.5 V olts
60 Lbs.
EM-2 1200
23.0 @ 12.5 V olts
24.3 @ 13.5 V olts
12.0 @ 24.5 V olts
49 Lbs.
EM-3 2200
46.0 @ 12.5 V olts
46.0 @ 13.5 V olts
24.0 @ 24.5 V olts
90 Lbs.
EM-7 800
15.0 @ 12.5 V olts
15.9 @ 13.5 V olts
10.0 @ 24.5 V olts
41 Lbs.
Table 1-6 IN--WALL EVAPORATORS
EVAP.
CFM Amps (High Speed) Amps (Med. Speed) Amps (Low Speed) Weight
IW-1 585
24.0 @12.5V
25.4 @13.5V
12.3 @12.5V
12.9 @13.5V
10.5 @12.5V
11.2 @13.5V
50 Lbs.
IW-2 450 21.7 @12.5V 11.3 @12.5V 7.7 @12.5V 20 Lbs.
IW-7 500 15.0 @12.5V 24.0 @12.5V 24.0 @12.5V 14 Lbs.
IW-14 405 18.0 @12.5V 24.0 @12.5V 7.5 @12.5V 35 Lbs.
1.7 CONDENSERS
Condensers are normally located on the outside of the
vehicle. Their primary function is to reject heat absorbed
by the refrigerant from the passenger compartment to
the outside air . Condensers are normally located on the
vehicle skirt or on the roof. If space in the vehicle skirt is
a problem, two (2) CM-2’ s or two (2) CM-3’s can be
stacked on each other with a kit available from Carrier
T ransport Air Conditioning. Carrier Transport Air
Conditioning condensers are listed in Table 1-7.
Table 1-7 CONDENSERS (Used With GEN 4 Or GEN 5 Series Evaporators)
Component
Type CFM (Approx) Amps Weight
CM-2 SKIRT MOUNTED 1600
14 @12.5
16 @ 25V
66 Lbs.
CM- 2 MICROCHANNEL SKIRT MOUNTED 1600
14 @12.5
16 @ 25V
45 Lbs.
CM-3 SKIRT MOUNTED 2400
21 @12.5V
24 @ 25V
76 Lbs.
CM- 3 MICRO CHANNEL SKIRT MOUNTED 2400
21 @12.5V
24 @ 25V
59 Lbs.
CM-4 SKIRT OR ROOF MT. 1300 13 @12.5V 59 Lbs.
CM-5 SKIRT MOUNTED 6000 41 @ 24V 202 Lbs.
CM-7
No longer Available
ROOF MOUNTED 1950
21 @12.5V
12 @ 25V
87 Lbs.
CM-11
No Longer Available
ROOF MOUNTED 1300 13 @12.5V 77 Lbs.
KR-4 ROOF MOUNTED 3500
44 @12.5V
22 @ 25V
187 Lbs.
KR-3 ROOF MOUNTED 2980
21.0 @12.5V
24.0 @ 25V
95 Lbs.
KR-2 ROOF MOUNTED 1990
12.0 @12.5V
15.0 @ 25V
70 Lbs.
CM-14 SKIRT MOUNTED 1800
27.5 @12.5V
30 @ 25V
92 Lbs.
CM-2 STKD (2 ea) SKIRT MOUNTED 3200 30 @12.5V 144 Lbs.
CM-3 STKD (2 ea) SKIRT MOUNTED 4800 45 @12.5V 168 Lbs.

Table of Contents

Related product manuals