Operation tips
Special function
A. Emergency switch:
a) Switch on the emergency switch in when the unit is in stop mode, and the unit operates on AUTO, AUTO SPEED,
    24°C setting; if you turn on the emergency switch when the unit is in start mode, the unit will stop operation.
b) Malfunction history list checks: In cooling or heating mode, using the remote controller set to automatic wind
    speed, press the SWING button 6 times to get the recent history of faults, the duration; the details of the buzzer
    ringing or the frequency of the timing lights ashing, in order to obtain the recent fault code.
B.Temperature compensation:
   In the heating mode, temperature compensation range is in the range of -14 ~ 0°C.
   Set the temperature consumption in the Heating mode using a remote controller, at 30°C as the reference point,
   press the sleep switch 7 times, and the buzzer ring 2 times; that’s how the unit enters temperature consumption 
   mode. Temperature consumption data = current temperature. In the cooling mode at -30°C, the temperature 
   compensation is in the range of -7 ~ +7 °C. Set the temperature consumption in the Cooling mode using the 
   remote controller’s cooling mode, at 23°C as the reference point, press the sleep button 7 times in 5 seconds; th
   buzzer rings twice, and the unit enters  temperature consumption mode. Temperature. consumption data current 
   temperature of -23°C
C. Deliberate Defrost:
    In the heating mode, at high speed, set the temperature at 30°C, and press the sleep button 6 times; the buzzer
    rings 3 times and the unit enter manual defrost mode.
D. Auto start function:
    When the unit is on, press the sleep button 10 times within 5 seconds; the buzzer rings 4 times and unit enters
    auto restart mode; press the sleep button 10 times within 5 seconds and the buzzer rings twice to indicate exiting
    of the auto restart function .
    The memory information: on/o condition, mode, fan speed, setting temp., swing position.
E. Room card function:
    Room card function can be switched on using the remote control device.
    Press the light button 12 times using remote control device; if the buzzer rings 4 times then the room card is valid,
    and= if the buzzer rings twice, then the room card is invalid.
Note:
If a wired controller is being used, then special functions of A, B, C and D need to be implemented in accordance 
with the wired controller manual. The E function is to be set up by the installation personnel during debugging and 
installation.