19
TECHNICAL PARAMETER
MODEL PR
PLUS
CAPACITY(Dual)
Max 3/6kg
e=d=1/2g
Max 6/15kg
e=d=2/5g
Max 15/30kg
e=d=5/10g
DISPLAYS: 6/5/5(Total price / Weight / Unit price)
DISPLAY DESIGNATORS ZERO, TARE, STABLE, AC POWER, BATTERY
MAXIMUM TARE - 2.999kg - 5.998kg - 9.995kg
TEMPERATURE -10 ~ +40℃℃
POWER SOURCE AC 220 - 240V,50 - 60Hz, PB 4V 4Ah
POWER CONSUMPTION APPROX. 4W
PLATTER SIZE(mm) 322W)x212(D)
ERROR MESSAGES
Table : Error Message
Error
Message
on Display
Description Solution
"Err 0" The "Err 0" occurs when scale is not stable. Remove unstable facts.
"Err 1"
The "Err 1" occurs when a current zero point has
shifted from the last span calibration.
Please call your CAS dealer.
"Err 3" The "Err 3" is an overload error. Please remove the weight.
"Err 4" The "Err 4" is leakage of payment. Scale needs more payment.
"Err 5" The "Err 5" means there is already tare. Remove the tare.