4 - INSTRUMENTS/CONTROLS
45
Field Tracker® Controls (If Equipped)
A24293
6. MANUAL/AUTOMATIC SWITCH - Push the switch forward to operate the Field Tracker® in
the Automatic Mode. Push the switch to the rear to operate the Field Tracker® in the
Manual Mode.
7. BALANCE CONTROL - Used to level the header when the Field Tracker® is in the
automatic mode and the header is lowered. Turn the control clockwise to lower the right
end of the header. Turn the control counterclockwise to lower the left end of the header.
8. SENSITIVITY CONTROL - Used to adjust the rate at which the Field Tracker® will react to
changes in terrain when the Field Tracker® is in the automatic mode and the header is lowered.
Turn the control clockwise to increase sensitivity. Turn the control counterclockwise to decrease
sensitivity.
At maximum sensitivity the difference in height (relative to the ground) between each end of the
header before the Field Tracker
®
will tilt, is small. At minimum sensitivity a larger difference in
header height (from end to end) is required before tilting will occur.
9.
RESPONSE CONTROL - Used to adjust how quickly the Field Tracker
®
tilts the header when in
the automatic mode and the header is lowered. Turn the control clockwise to increase response.
Turn the controlcounterclockwise to decrease response.
NOTE: Field Tracker® is a registered trademark of HCC, Inc.