CONTROLLER
3 - 26
CX EXCAVATORS
PAST OVER LOAD CONDITION CHK5
R: Engine Load Ratio (CX210/CX240)
FT: Fuel Temperature (CX210/CX240)
TV: Throttle Volume
TR1: Transistor output has detected an over current
TR2: Transistor output has detected an over current
TR3: Transistor output has detected an over current
TR4: Not Used
While in the CHK2 screen, press and hold the Travel mode switch this will
allow you to view CHK5. CHK5 screen allows you to view PAST output
conditions if an over current was detected. DO NOT HOLD SWITCH
LONGER THAN 10 SECONDS. TRAVEL ALRM WILL SOUND. KEY WILL
HAVE TO BE TURNED OFF TO TURN OFF ALARM.
Note: To erase fault codes in CHK5 switch to DIAG5 and press the Work
mode switch for 10 seconds. The warning buzzer will sound. Turn OFF the
key switch to complete the process.
CHK MODE 2 H
5 TR1 0 0 0 0
R 0 0 0 0 % TR2 0 0 0 0
FT 0 0 0 0 F TR3 0 0 0 0
TV 0 0 0 0 % TR4 0 0 0 0